ELECTRICAL SPECIFICATIONS
Temperature Control (Position 5)....................... 32 - 4°F
Defrost Control... 60 hrs @ 40 mins with no door opening
Overtemperature Thermostat....................... 140 - 110°F
Defrost Thermistor.................................................70°F
Electrical Rating: 115V. AC, 60 Hz.................1 - 5 Amp.
Maximum Current Leakage................................0.5 mA
Maximum Ground Path Resistance...............0.14 Ohms
Energy Consumption.......507 kWh/yr for 20 cu/ft models
Energy Consumption.......520 kWh/yr for 22 cu/ft models
NO LOAD PERFORMANCE
Control Position: 5-5
And Ambient of:................................................... 90°F
Fresh Food, °F..................................................32 - 42
Frozen Food, °F.................................................. -5 - 5
Percent Running Time....................................... 45 - 65
REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum.............. 22 in.
Minimum Equalized Pressure
@ 70°F ................................................... 38 PSIG
@ 90°F.................................................... 49 PSIG
Refrigerant - R - 134a...................................... 4.06 oz.
Compressor .............................................. 690 BTU/hr
INSTALLATION
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation.
AT TOP............................................................. 1 inch
AT SIDES................................................... 0.125 inch
AT REAR.......................................................... 1 inch

Technical Data

Airflow
The evaporator fan forces air through the
evaporator into the freezer compartment.
Air from the evaporator is also forced through the
electronic damper to the top of the air tunnel,
through the fresh food compartment, and returns
to the evaporator.
The fresh food compartment receives chilled air
through an electronic damper at the bottom, rear
of the fresh food compartment. The damper is
controlled by the main control board. When open,
the damper allows chilled air from the freezer to
move into the fresh food compartment.
Air returns from the fresh food compartment to the
freezer compartment via two vents located to the
left and right of the air tunnel.
– 6 –