TMNF - 22
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT-RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
ELECTRICAL SPECIFICATIONS
Temperature Control {Position 5) ................ 7-(-11 )°F
Defrost Control ............................................ 60hrs @ 45 min
Overtemperature Thermostat ...................... 140-110°F
Defrost Thermistor ...................................... 65°F
Electrical Rating: 115V. AC 60 Hz ............... 11.6 Amp
Maximum Current Leakage ......................... 0.75 mA.
Maximum Ground Path Resistance ............. 0.14 Ohms
Energy Consumption .................................. 40 KWH/mo.
NO LOAD PERFORMANCE
Control Position MID/MID
and Ambient of:
Fresh Food, °F ........................................... 34-40
Frozen Food, °F ......................................... (-3) 3
Run Time, % .............................................. <45%
REFRIGERATION SYSTEM
Refrigerant Charge (R134a) ....................... 4.5 ounces
Compressor ................................................ 762 BTU/hr
Minimum Compressor Capacity .................. 22 inches
Minimum Equalized Pressure
@ 70°F ......................................................... 30 PSIG
@ 90°F ......................................................... 38.5 PSIG

Technical Data

IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation
of this information, nor can it assume any liability
in connection with its use.
INSTALLATION
Clearance must be provided for air circulation
AT TOP ....................................................................... 1"
AT SIDES .................................................................... 1/8"
w/ no door openings
AT REAR .................................................................... 1"
AIR FLOW
70°F
90°F
34-40
(-3) 3
<70%
REPLACEMENT PARTS
Board Asm. Temperature Control ........................... wr55x10085
Relay (PTCR) .......................................................... wr07x0240
Overload ................................................................. wr08x10015
Run Capacitor (15 uF) ............................................ wr62x10079
Defrost Thermostat ................................................ wr50x10015
Defrost Heater Asm. ............................................... wr51x10038
Condenser Fan Motor ............................................. wr60x10053
Evaporator Fan Motor ............................................. wr60x10043
Board Asm. Main Control ........................................ wr55x10086
Thermistor (FF) ....................................................... wr55x10087
Thermistor (FZ) ...................................................... wr55x10088
Thermistor (Evap.) .................................................. wr55x10089
– 2 –
COLD AIR
MIXED AIR
WARMER AIR
238C1616P001