NEC N8100-1447F User Manual page 245

Table of Contents

Advertisement

Installation
Install a DIMM in the following procedure.
1.
See the section "Preparing for Installation and Removal" described earlier to prepare.
2.
Remove the left side cover as described earlier in this chapter.
3.
Firmly hold the server with your both hands so that its left side faces upward, and bring it
down slowly and gently.
4.
Open the levers at both ends of the socket.
5.
Push the DIMM to the socket straight.
If the DIMM is inserted into the DIMM socket, the lever is automatically closed.
IMPORTANT:
force to the lever.
NOTE:
much pressure can damage the socket. Keyed DIMMs insert only one
way.
6.
Close the lever securely.
7.
Install the remove components.
8.
Turn on the power of the server. Make sure that no error message appears in the POST.
If an error message appears, write down the message and contact your service
representative for the maintenance.
9.
Run BIOS SETUP utility and check to see that the installed DIMMs are correctly
recognized. See Chapter 4 for details.
10.
Run BIOS SETUP Utility to set the "Reset Configuration Data" in the "Advanced" menu
to "Yes."
This is required to update the hardware configuration information. See Chapter 4 for
details.
11.
Set the paging file size to the recommended value or larger. See Chapter 5 for details.
Key slot
To avoid damaging the lever, do not apply an excess
Use extreme care when installing a DIMM. Applying too
Key
Upgrading Your Server 9-35