Quincy Compressor QSI Series Instruction Manual page 86

Qsi series industrial rotary screw air compressors
Hide thumbs Also See for QSI Series:
Table of Contents

Advertisement

Appendix B - Technical Data
QSI 600
Full Load Operating Pressure
Maximum Operating Pressure
Minimum Operating Pressure
Maximum Ambient Operating Temperature:
Less Cabinet
With Cabinet
Minimum Ambient Operating Temperature
Compressor Drive Motor
Rotor Diameter
Male Rotor Speed
Female Rotor Speed
Rotor Tip Speed
Inlet Capacity
Displacement at Operating Speed
Volumetric Efficiency
Aftercooling
Heat Rejection:
Fluid Cooler
Aftercooler
Aftercooler Approach (standard conditions)
Maximum Allowable Static Backpressure
Fan Motor
Fan Motor
Fan Flow
Water-cooled Cooling
Recommended Inlet Water Pressure
Vent Fan Motor
Aftercooler Approach to Cooling:
Water Temperature
Water Flow less Aftercooler at: 50°F
Water Flow with Aftercooler at: 50°F
Compressor Fluid
Total Fluid Capacity
Reservoir Fluid Capacity
Fluid Flow
Typical Fluid Carryover
Normal Airend Discharge Temperature
Sound (at 1 meter)
Unenclosed (AC/WC)
Standard Cabinet (AC/WC)
Low Sound Cabinet (AC)
80
psig
psig
psig
°F
°F
°F
HP
mm
rpm
rpm
m/sec.
acfm
cfm
%
BTU/min.
BTU/min.
°F
in./H
O
2
HP
rpm
cfm
psig
HP
°F
gpm
70°F
gpm
90°F
gpm
gpm
70°F
gpm
90°F
gpm
gallons
gallons
gpm
ppm
°F
dB(A)
dB(A)
dB(A)
Quincy Compressor-QSI
S
TANDARD
100
110
115
125
75
118
110
35
125
255
1785
1190
23.83
630
623
*data not available*
*data not available*
4674
4911
1016
1018
6
0.125
5
1790
12200
40-100
1/9
9-10
*data not available*
15
16
25
27
*data not available*
12
14
21
24
13
11.8
35
1-3
190-195
87/86
82/81
*data not available*
®
125
150
140
165
150
1790
1193
23.9
615
594
5292
5972
1017
1025
17
38
55
38
16
27
45
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents