Section IX - Troubleshooting

Probable Causes:
Excessive Fluid Consumption:
T
OO HIGH FLUID LEVEL IN THE RECEIVER
P
LUGGED SCAVENGER LINE
H
IGH DISCHARGE TEMPERATURE
L
OW RESERVOIR PRESSURE WITH FULLY OPEN INLET
VALVE
F
AULTY OR DAMAGED SEPARATOR
L
EAK IN FLUID LINES
S
,
EAL FAILURE
LEAKS
I
NCORRECT FLUID
Frequent Air Cleaner Clogging:
C
OMPRESSOR OPERATING IN HIGHLY CONTAMINATED
ATMOSPHERE
A
IR CLEANER NOT ADEQUATE FOR CONDITIONS
54
Corrective Action:
A
DJUST FLUID LEVEL TO RECOMMENDED FLUID
LEVEL BY DRAINING THE RESERVOIR
LEVEL GAUGE AS A GUIDE
C
LEAN SCAVENGER LINE ORIFICE AND TUBE
C
ORRECT IN ACCORDANCE WITH THE INSTRUCTIONS
"H
IN
IGH DISCHARGE AIR TEMPERATURE
THIS TROUBLESHOOTING GUIDE
R
ESERVOIR PRESSURE SHOULD NOT FALL BELOW
PSIG
WHEN RUNNING LOADED
CFM
REQUIREMENT AND MINIMUM PRESSURE CHECK
.
VALVE
C
HANGE AIR
C
HECK FOR LEAKS AND CORRECT
R
EPLACE SEAL ASSEMBLY AND O
U
SE RECOMMENDED FLUIDS ONLY
C
OMPRESSOR
U
SE REMOTE AIR INTAKE MOUNTING
U
SE SPECIALIZED AIR FILTER
A
UTHORIZED
Quincy Compressor-QSI
.
.
. C
/
.
FLUID SEPARATOR
.
-
F
S
.
LUID
ECTION
. C
ONTACT AN
Q
D
UINCY
ISTRIBUTOR
®
. U
SE FLUID
.
"
SECTION OF
50
HECK SYSTEM
.
RINGS
. S
EE
.
.

Hide quick links:

Advertisement

Table of Contents
loading