Quincy Compressor QSI Series Instruction Manual page 84

Qsi series industrial rotary screw air compressors
Hide thumbs Also See for QSI Series:
Table of Contents

Advertisement

Appendix B - Technical Data
QSI 370
Full Load Operating Pressure
Maximum Operating Pressure
Minimum Operating Pressure
Maximum Ambient Operating Temperature:
Less Cabinet
With Cabinet
Minimum Ambient Operating Temperature
Compressor Drive Motor
Rotor Diameter
Male Rotor Speed
Female Rotor Speed
Rotor Tip Speed
Inlet Capacity
Displacement at Operating Speed
Volumetric Efficiency
Aftercooling
Heat Rejection:
Fluid Cooler
Aftercooler
Aftercooler Approach (standard conditions)
Maximum Allowable Static Backpressure
Fan Motor
Fan Motor
Fan Flow
Water-cooled Cooling
Recommended Inlet Water Pressure
Vent Fan Motor
Aftercooler Approach to Cooling:
Water Temperature
Water Flow less Aftercooler at: 50°F
Water Flow with Aftercooler at: 50°F
Compressor Fluid
Total Fluid Capacity
Reservoir Fluid Capacity
Fluid Flow
Typical Fluid Carryover
Normal Airend Discharge Temperature
Sound (at 1 meter)
Unenclosed (AC/WC)
Standard Cabinet (AC/WC)
Low Sound Cabinet (AC)
78
psig
psig
psig
°F
°F
°F
HP
mm
rpm
rpm
M/sec.
acfm
cfm
%
BTU/min.
BTU/min.
°F
in./H
O
2
HP
rpm
cfm
psig
HP
°F
gpm
70°F
gpm
90°F
gpm
gpm
70°F
gpm
90°F
gpm
gallons
gallons
gpm
ppm
°F
dB(A)
dB(A)
dB(A)
Quincy Compressor-QSI
S
TANDARD
100
110
115
125
75
120
115
32
75
204
1785
1190
19.07
372
370
403.1
92.3
91.5
2808
2957
522
3-5
0.125
3
1750
6800
40-100
1/9
13-18
4.7
7.1
15.2
6.2
9.2
19.4
15
11
24.5
1.5-5
175-195
83/83
79/79
76
®
125
150
140
165
100
1790
1193
19.12
368
364
404.2
91
90.1
3184
3581
5.5
8.9
24.6
7.3
11.5
29.5

Hide quick links:

Advertisement

Table of Contents
loading