Rough-in Niche (Left Hand)

2
Connect #8 guage (10mm
wire to house electrical panel or approved local ground.
An approved ground may be an 8 foot long ground rod
(3 meter long earth rod), a plate electrode, or other
acceptable bond. Check your local building code for
reqiurements.
Electrical outlet: 240V,
20A, 3 wire to be on a 20A
GFCI- protected circuit.
IMPORTANT: This illustration shows the
installed position of the waste stubout when
connected to the shower drain. If the stubout
is installed before the shower unit, leave enough
flex in the waste line to allow the end of the
stubout to be blocked temporarily (see page 11)
in a position under flush to the floor surface.
This will allow the shower unit to slide across
the floor into position without having to lift it.
IMPORTANT: The shower drain is designed
to connect to a 2 inch (50 mm) ABS or PVC (as
approved by local codes/standards) waste
stubout.
The end of the 2 inch (50 mm) waste
stubout must be located to these
dimensions within 1/4 inch (6 mm).
) minimum solid copper bond
40"
FINISHED
WALL
SURFACE
60"
FINISHED
MINIMUM
16"
55"
FINISHED
WALLS
FINISHED
FLOOR
MATERIAL
16-3/8"
2" WASTE
STUBOUT
8
WASHING MACHINE
OUTLET BOX
HOSE BIBB (2)
TWO (2) 1/2" HOT & COLD
WATER SUPPLY LINES
18"
36"
FINISHED
WALL
SURFACE