Rough-In Corner (Left Hand) - Jacuzzi J-DREAM Owner's Manual

J-dream shower system
Hide thumbs Also See for J-DREAM:
Table of Contents

Advertisement

J-Dream
Owner's Manual

Rough-in Corner (Left Hand)

Connect #8 gauge (10 mm
bond wire to house electrical panel or approved local
ground. An approved ground may be an 8 foot long
ground rod (3 meter long earth rod), a plate electrode,
or other acceptable bond. Check your local building
code for reqiurements.
Electrical outlet 240V, 20A,
3 wire to be on a 20A GFCI
protected circuit.
IMPORTANT: This illustration shows the
installed position of the waste stubout when
connected to the shower drain. If the stubout
is installed before the shower unit, leave
enough flex in the waste line to allow the end
of the stubout to be blocked temporarily (see
page 11) in a position under flush on the floor
surface. This will allow the shower unit to slide
across the floor into position without having to
lift it.
IMPORTANT: The shower drain is designed
to connect to a 2 inch (50 mm) ABS or PVC (as
approved by local codes/standards) waste
stubout.
The end of the 2 inch (50 mm) waste stubout
must be located to these dimensions within 1/4
inch (6 mm).
2
) minimum solid copper
40"
FINISHED
WALL
SURFACE
2" WASTE
STUBOUT
60"
FINISHED
MINIMUM
16"
55"
FINISHED
WALLS
18"
16-3/8"
11-5/8"
6
WASHING MACHINE
OUTLET BOX
HOSE BIBB (2)
TWO (2) 1/2" HOT & COLD
WATER SUPPLY LINES
36"
FINISHED FLOOR
MATERIAL