Installation and user guide
Inverter
7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3
EN
As at 06/2012, Mat. no. 758 266-AA

Advertisement

Table of Contents
loading

Summary of Contents for Platinum 7000 R3

  • Page 1 Installation and user guide Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3 As at 06/2012, Mat. no. 758 266-AA...
  • Page 2 Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 3: Table Of Contents

    Display Operation display Isolate from generator field (DC isolator) Menu Operate and navigate in the menu Menu tree Settings menu Information menu Service menu Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 4 Contents Maintenance and cleaning 7 .1 Maintenance 7 .2 Cleaning Errors and troubleshooting Error display Event list Technical data Taking out of operation Disposal Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 5: Introduction

    ▪ Manufacturer's warranty from Diehl AKO Stiftung & Co. KG 1.3 Symbols used 1.3.1 Structure of warnings SIGNAL WORD Type, source and consequence of the hazard! f Measures to avoid the hazard. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 6: Symbols On Product And Packaging

    Notes give tips on how to work easily and safely or contain further information. 1.4 Symbols on product and packaging The following label is affixed to the inverter. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 7: Safety

    – National and international regulations and provisions ▪ Ensure that all protection devices are working correctly. ▪ Observe conditions of use; see "Technical data" on page 42. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 8: Installation

    1. Open the box. 2. Pull out the brief guide (1) and wall bracket (2) at the side. 3. Remove the inverter (with padding) from the box. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 9: Assembly

    Wear safety shoes during assembly and disassembly. f Ensure that you have firm and secure footing. 3.3.2 Assembly Diehl Controls recommends that the inverter not be installed in living quarters. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 10 1. Choose the assembly location, taking into account dimensions and distances 2. Fix the wall bracket to the assembly wall with suitable fixing materials. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 11 5. Ensure that the inverter is fitted correctly on the wall bracket. 6. Secure the inverter by tightening the safety screws on the sides. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 12: Connection

    Observe max. fuse protection permitted on the AC voltage side of 32 A. f Diehl Controls recommends a type C cable isolator switch. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 13 AC screw connection and seal. 3. Feed the AC voltage connection line into the housing from below. 4. Tighten the AC screw connection. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 14 Make sure that the DC isolator or a central isolation device can be accessed freely. f Do not earth PV modules. The inverter does not have a transformer. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 15 4. To ensure the type of protection, place protective caps on unused plug connectors. String 2 String 1 Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 16 ▪ Twisted wire pair of a CAT-5 cable Connection 1. Unfasten the network screw connections (7 , IN) and (8, OUT) with seal from the underside of the inverter. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 17 1 2 3 4 5 6 Cable B: Terminal 4 t Ensure that signal lines A and B are B A B not connected incorrectly. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 18 – Last participant in the network: Put terminating plug into OUT socket 3.4.5 Final tasks t Secure the service cover on the inverter with six screws. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 19: Initial Operation

    If data cannot be entered, the inverter displays the start screen. ▪ During initial operation, all inverters connected to the PLATINUM network are blocked. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 20: Initial Operation Menu

    Changing the date and time can cause saved data to be overwritten or lead to gaps in data logging. During initial operation, the date and time must be entered correctly once. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 21 – Confirm NEXT NUMBER? with OK for every inverter in the network in the order desired. The next number in each case will be assigned to the inverter. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 22 The date and time must be confirmed with OK, otherwise initial operation cannot be completed. Once the date and time have been entered, the TIME SETTINGS screen appears; see "Settings menu" on page 30. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 23 Depending on the requirements of the network operator, the following additional settings must be made in the service menu; see "Service menu" on page 33: ▪ Grid support ▪ Power reduction Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 24: Operation

    ▪ Inverter not in feed-in mode LED off Both LEDs flash at same time The inverter is running a network scan or making parameter settings. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 25: Operation Display

    Screen 2: Standardised power data (if configured) (6) Standardised yield generated for the period displayed; in the example: yield generated today (7) Maximum standardised power achieved today Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 26 – Each day is represented by one bar in the monthly display (1st – 31st). – Each month is represented by one bar in the yearly display (Jan. – Dec.). Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 27: Isolate From Generator Field (Dc Isolator)

    ▪ Diehl Controls recommends switching off the mains voltage (AC) before switching off the DC isolator to minimise wear to the contacts. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 28: Menu

    ▪ If entering information: to the next/previous digit ▪ Back to the main menu without making changes ▪ Select setting and back to the main menu ▪ Open selected submenu Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 29: Menu Tree

    Rebate System Plant size Standardisation Meter 2 Information Operating data System data Inverter type Inverter version The menu options are described in tables below. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 30: Settings Menu

    ▪ Set the alarm volume for the built-in buzzer on this inverter. 0 ... 3 Possible values: 0 ... 3 Factory setting: 0 (alarm off) Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 31 Meter 2 Meter 2 counts the energy fed in since the last reset. ▪ Do not reset meter 2. Back ▪ Reset meter 2. Reset Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 32: Information Menu

    (7) Serial number (8) Configured standard (9) Firmware version (10) PLATINUM Network version * ENS = Device for monitoring the network with allocated control elements Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 33: Service Menu

    The parameters are structured in several levels, with the specific value displayed on the lowest level. Parameters can only be modified by certified persons with the PLATINUM service tool. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 34 In MPP Shadow mode, the ideal yield may not be achieved because only a little energy is fed in during the MPP search. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 35 6.5.6 Power Reduction service menu Power reduction Maximum Enter the maximum power for this inverter according to the power specifications of the network operator. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 36: Maintenance And Cleaning

    The inverters must not be cleaned with a steam cleaner. To ensure cooling, clean the ventilation slots regularly with ▪ a vacuum cleaner ▪ soft brush ▪ pressured air Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 37: Errors And Troubleshooting

    2. To exit the error display, press the  button. The event list is displayed. 3. Exit the event list by pressing the ESC button. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 38 1. To exit the error display, press the  button. The event list is displayed. 2. Exit the event list by pressing the ESC button. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 39: Event List

    ▪ Check DC connection polarity ▪ Check isolation of PV modules Isolation error between ▪ Check isolation of PV cables PV+ and earth / PV– and earth Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 40 Mains frequency limit exceeded If the inverter is supplied with emergency 2110 or undershot power from a different mains frequency: ▪ No measures required Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 41 ▪ Inform service of error code if required 4000 Diagnosis support in service situation 4990 The inverter stores the warning in the event list Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 42: Technical Data

    0.7 ind ... 0.7 cap Earth connection monitoring Efficiency 7000 R3 Max. efficiency 98.4 % Euro efficiency 97 .7 % Type name 7000 R3-MDX Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 43 14000 R3 16000 R3 98.4 % 97 .8 % 97 .9 % 98.0 % 98.0 % 9000 R3-MDX 11000 R3-MDX 14000 R3-MDX 16000 R3-MDX Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 44: Ambient Conditions

    Storage capacity sufficient for operating time of 30 years The technical data is valid for a maximum height of 2,000 m above sea level. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 45: Taking Out Of Operation

    Ensure that you have firm and secure footing. The procedure for taking inverters out of operation is the reverse of that for installation and assembly. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 46: Disposal

    ▪ Do not dispose of PLATINUM inverters in household waste. ▪ Diehl Controls takes back complete PLATINUM inverters. ▪ PLATINUM inverters can be disposed of via municipal waste management for electrical devices. Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 47 Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3...
  • Page 48 Diehl AKO Stiftung & Co. KG PLATINUM Service Pfannerstraße 75 Tel.: +49 7522 73-777 88239 Wangen im Allgäu, Germany Fax: +49 7522 73-737 Tel.: +49 7522 73-700 service.platinum@diehl-controls.com Fax: +49 7522 73-710 platinum@diehl-controls.com www.diehl.com/photovoltaics...