Technical data
Interfaces
DC input
DC isolation device
Reverse voltage protection (DC)
AC output
PLATINUM network
Service interface

Ambient conditions

Operating temperature range
Max. temperature for rated power
Storage temperature
Max. humidity
Protection class
Contamination level
Inverter data
Dimensions (H x W x D)
Weight
Switching concept
Cooling concept
Protection class / overvoltage
protection
Overvoltage category
Optical display
Integrated datalogger
The technical data is valid for a maximum height of 2,000 m above sea
level.
44
... R3
Multi-Contact MC4
Switch integrated in inverter for isolation from
generator field
Yes
Spring terminal
EIA 485, 2 x RJ45 Western Modular, add. plug
with screw terminals
EIA 232, SubD 9-pole socket
... R3
–20 °C to +60 °C
+45 °C
–25 °C to +80 °C
95 %
IP65 in accordance with DIN EN 60529
II, external and internal use possible
... R3
629 x 547 x 290 mm
45 kg
Transformerless, DIVE, RACE,
ENS in accordance with VDE 0126-1-1
Convection cooling
I / III
DC side: II
AC side: III
Full graphic LCD, 170 x 76 pixels
Storage capacity sufficient for operating time of
30 years