LED Descriptions

8.12 sercos Master

LED
Color
STA
Duo LED red/green
Name in
(green)
the device
(green)
drawing:
COM 0
(green)
(green)
(green)
(green)
(off)
ERR
Duo LED red/green
Name in
(red)
the device
(red)
drawing:
COM 1
(red)
(red)
(red)
(red)
(red)
(red)
(off)
L/A/RJ45
LED green
Ch0 & Ch1
(green)
(green)
(off)
LED yellow
RJ45
Ch0 & Ch1
-
Indicator state
Definition
Off
The indicator is constantly off.
Blinking
The indicator turns on and off with a frequency of 2,5 Hz: on for 200 ms, followed by off for 200 ms.
Single Flickering
The indicator turns on and off with a frequency of approximately 10 Hz: on for approximately 50 ms,
followed by off for 50 ms.
Double Flickering
The indicator turns on / off / on each for approximately 50 ms, followed by off for 500 ms.
Flickering
The indicator turns on and off once: on for approximately 50 ms, followed by off for 50 ms.
Single Flash
The indicator shows one short flash (200 ms) followed by a long off phase (1,000 ms).
Double Flash
The indicator shows a sequence of two short flashes (each 200 ms), separated by a short off phase (200
ms). The sequence is finished by a long off phase (1,000 ms).
Triple Flash
The indicator shows a sequence of three short flashes (each 200 ms), separated by a short off phase (200
ms). The sequence is finished by a long off phase (1,000 ms).
Quadruple Flash
The indicator shows a sequence of four short flashes (each 200 ms), separated by a short off phase (200
ms). The sequence is finished by a long off phase (1,000 ms).
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM39EN | Revision 39 | English | 2014-01 | Released | Public
The subsequent table describes the meaning of the LEDs for the PC card
cifX Real-Time Ethernet Master when the firmware of the sercos Master
protocol is loaded to the device.
State
Blinking
Flickering
Single Flash
Double Flash
Triple Flash
On
Off
Blinking
Flickering
Double Flickering
Single Flickering
Quadruple Flash
Triple Flash
Double Flash
Single Flash
Off
On
Flickering
Off
-
Table 44: LEDs sercos Master
LED State Definition for sercos Master for STA and ERR LEDs
Table 45: LED State Definition for sercos Master for the STA and ERR LEDs
Meaning
CP0: Communication phase 0
Master isn't configured and is in NRT. After a status change this
isn't indicated again
CP1: Communication phase 1
CP2: Communication phase 2
CP3: Communication phase 3
CP4: Communication phase 4
NRT: Non Real-time Mode
Error in the configuration database.
Boot-up was stopped due to an error.
Slave is missing.
Channel Init was executed at the Master.
No Master license present in the device
DPM Watchdog has expired.
Internal Stop of the bus cycle
Bus Sync Error Threshold
No error
Link: A connection to the Ethernet exists
Activity: The device sends/receives Ethernet frames
The device has no connection to the Ethernet
This LED is not used.