Market Forge Industries Premier PS-3E Owner's Manual page 24

Premier series electric countertop convection steamer installation, operation, maintenance and parts
Hide thumbs Also See for Premier PS-3E:
Table of Contents

Advertisement

REMOVAL OF SCALE DEPOSITS (Continued)
NOTICE: Contact the factory, the factory representative or local
service company to perform maintenance and repairs.
WARNING: Read and follow instructions on the CLR bottle. Use
plastic or rubber gloves to avoid skin contact. If CLR comes in
contact with skin, rinse with clean water.
1. Drain steam generator by setting the main power switch to OFF. Set cooking timer to "OFF".
2. Set the main power switch to DELIME.
3. Delime port (A) is located on left side at rear of unit. Unscrew hex plug from elbow to allow
CLR solution to be poured in using a tube and funnel. Pour in 28 ounces of solution into the
generator (pour slowly to avoid spillage). Remove tube and funnel.
4. Screw the hex plug back into the elbow so that it is sealed.
5. Turn main power switch to ON.
6. Allow steamer to remain in READY cycle for 1-1/2 hours, then turn main power switch OFF
and allow generator to drain.
7. FLUSH CYCLE: Turn main power switch to ON. When READY light comes on, turn main
power switch to OFF to flush generator. Repeat this step three times to completely flush
generator.
8. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean cloth.
Dry with soft cloth. Leave compartment door open when not in use.
The steamer is now ready for use. Turn off for overnight shutdown.
24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier ps-6e

Table of Contents