Pressure Transducer - Graco 824-002 Owner's Manual

Electric, airless paint sprayer 2750 psi (195 bar) maximum working pressure a series
Table of Contents

Advertisement

WARNING
INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 9.
NOTE: See Fig. 30 for this procedure.
1. Remove the displacement pump. See page 21.
2. Use a pull–twist motion to remove the transducer
(29) from the pump manifold (101).
3. Clean paint residue from the hole in the manifold;
do not scratch the surface of the hole.
4. Lightly apply oil to the o-ring of the new transducer.
5. Install the transducer in the pump manifold, while
guiding the o-ring and backup ring into place.
6. Align the holes in the transducer as shown by the
arrows in Fig. 30.
7. Install the displacement pump. See page 21.

Pressure Transducer

29
101
Fig. 30
02841A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nova plus 824-002

Table of Contents