3.7.2  Charging  with  Kinectrics  Equipment
3.7.2.1  Connec ng
1.
The  equipment  requires  the  use  of  a  SPEC  Pak  adapter  for  connec ng  to  the  DC  input  socket  on  the  unit's  control  
panel  (Fig.  1,  F1).
2.
When  connec ng  one  to  two  Kinectrics  units  a  SPEC  Pak  to  2  x  50  A  Anderson  connectors  adapter  can  be  used  to  
connect  the  Kinectrics  equipment  directly  to  a  Cygnus  with  suitable  extension  cables.  These  are  available  from  
the  manufacturer.  Refer  to  Appendix  3  (6.3.5)  for  an  example  setup.
3.
Up  to  eight  Kinectrics  units  can  be  connected  to  a  single  unit.  A  junc on  box  is  required  when  connec ng  be-­‐
tween  three  and  four  Kinectrics  units.
4.
Two  junc on  boxes  are  required  when  connec ng  between  five  and  eight  Kinectrics  units.
5.
Once  the  Kinectrics  equipment  has  been  posi oned  suitably,  the  extension  cables  connected  and  safely  run  back  
to  Cygnus,  the  equipment  can  be  connected.
6.
Connect  the  SPEC  Pak  connector  to  the  unit.  Refer  to  Appendix  2  (6.2.1)  for  further  informa on  on  using  the  
SPEC  Pak  connector.
3.7.2.2  Disconnec ng
1.
Remove  the  SPEC  Pak  connector  from  the  unit.  Refer  to  Appendix  2  (6.2.2)  for  further  informa on  on  using  the  
SPEC  Pak  connector.
2.
Disconnect  the  remaining  cables  and  any  junc on  boxes.
3.7.3  Charging  with  AC  Grid  Supply  or  Secondary  Power  System
The  unit  can  be  charged  via  a  220  -  240V  AC  supply  from  either  the  AC  grid  supply  or  a  secondary  power  system.  To  con-­‐
nect  an  AC  supply  to  Cygnus:
1.
Connect  the  220  -  240V  AC  supply  lead  to  the  AC  In  socket  (Fig.  1,  E1)  on  the  control  panel.
2.
The  RCC-03  (Fig.  1,  C2)  will  display  a  message  to  confirm  that  the  AC  supply  has  been  connected  successfully.
3.
Press  SET  to  clear  the  message.
4.
The  RCC-03  input  voltage  (Fig.  4,  A1)  will  display  the  external  voltage  being  applied  to  the  charge  facility  of  the  
unit.
5.
The  unit  charges  its  ba ery  bank  automa cally,  regula ng  the  charge  cycle  and  ensuring  that  the  
ba eries  are  not  over  charged.
6.
Once  the  unit  is  fully  charged  the  Smartgauge  (Fig.  1,  C1)  will  display  'C100'  indica ng  that  it  is  100%  full.
Cygnus  requires  a  minimum  13  A  supply  for  AC  charging.  Ensure  that  your  power  supply  and  any  inter-­‐
connec ng  cables  and  fuses  have  this  minimum   a vailable  current  ra ng.
It  is  recommended  that  the  unit  charges  for  a  further  2  hours  once  it  has  reached  100%.  This  allows  
the  ba ery  bank  to  fully  absorb  the  charge.