Connec ng  the  Cygnus  Portable  Solar  Generator
2.4.1 Earth  a achment:  Installing  the  Op onal  Earth  Rod:
1.
Find  a  suitable  place  to  drive  the  earth  rod  into  the  ground.  The  earth  rod  should  be  driven  down  at  least  
600mm  into  the  ground  using  a  mallet  and  placed  as  near  to  the  unit  as  possible.
2.
Check  the  earth  cable  is  securely  clamped  to  the  rod.  The  clamp  may  need  re ghtening  a er  driving  the  earth  
rod  down.
3.
On  the  control  panel,  locate  the  earth  bolt  (Fig.  1,  C5)  undo  the  earth  bolt  wing  nut  and  remove  one  of  the  
washers.  Then  slide  the  ring  terminal  at  the  end  of  the  earth  cable  onto  the  earth  bolt.  Replace  the  washer  and  
ghten  the  wing  nut.
A  protec ve  earth  must  be    connected  to  the  unit  in  compliance  with  applicable  local  standards  and  
regula ons.  This  can  be  done  either  by  connec ng  to  a  suitable  exis ng  electrical  earth,  or  by  using  an  
op onal  earth  rod  supplied  by  the  manufacturer.
2.4.2 Connect  the  Inputs:
There  are  a  number  of  means  available  to  charge  the  unit.  Instruc ons  on  how  to  connect  charging  inputs  (e.g.  solar  PV,  
wind  turbines,  Kinectrics  equipment)  are  available  as  appendices  to  this  manual  or  included  with  those  products  at  the  
point  of  purchase.  All  user  manuals  can  also  be  downloaded  from  the  manufacturer's  website  at  www.fireflysolar.net
It  is  also  possible  to  operate  the  unit  only  using  the  internal  ba ery  bank,  without  external  inputs  connected.
Care  must  be  taken  to  ensure  that  the  correct  connec ons  are  made  to  avoid  the  risk  of  electrocu on  
or  possible  damage  to  the  unit's  internal  components.
Ensure  that  the  cumula ve  power  of  connected  consumers  does  not  exceed  the  maximum  power  out-­‐
put  of  your  unit–  refer  to  the  ra ng  plate  to  ascertain  the  unit's  maximum  power  output.
All  connected  consumers  must  be  fit  for  purpose–  refer  to  their  ra ng  plates  and  manuals  to  ascertain  
the  required  input.
When  Cygnus  is  connected  to  an  external  AC  supply,  the  output  voltage  is  transferred  from  its  input.  
In  this  case  the  unit  will  not  modify  the  AC  output:  Consumers  will  be  supplied  with  an  output  
iden cal  to  the  source.