Download Print this page

SummerAire SBB Installation And Owner's Operating Instructions

Wood/oil combination furnace

Advertisement

Quick Links

INSTALLATION AND OWNER'S OPERATING INSTRUCTIONS
READ
BEFORE OPERATING YOUR SUMMERAIRE FURNACE.
THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER
AND WHERE REQUIRED BY LAW, A LICENCED TECHNICIAN.
INSTALLATION and OPERATING
INSTRUCTIONS
SUMMERAIRE
GAMME SMO
SBB WOOD/OIL COMBINATION FURNACE
AND UNDERSTAND THESE INSTRUCTIONS
SAVE THESE INSTRUCTIONS FOR REFERENCE
SUMMERAIRE MFG.
PETERBOROUGH, ONTARIO
FOR
SERVICE CALL:
NAME : __________________________
ADDRESS : ______________________
__________________________________
TELEPHONE : ____________________
SBB

Advertisement

loading
Need help?

Need help?

Do you have a question about the SBB and is the answer not in the manual?

Questions and answers

Daniel Guay
January 18, 2025

Pourquoi la **** du souffleur fonctionne sans arrêt? Y a t'il un piton pour régler cela?

1 comments:
Mr. Anderson
May 14, 2025

The SummerAire SBB blower may run continuously if the limit control has been triggered due to excessive heat, such as after an extreme wood fire or operation without electrical power. This is a safety feature to prevent overheating. There is no mention of a specific button to adjust this; instead, the operation of the limit control must be checked to ensure it is functioning properly before returning the furnace to service.

This answer is automatically generated

Daniel R Guay
January 18, 2025

Why the **** of the blower dosn'stop?

1 comments:
Mr. Anderson
May 14, 2025

The blower of the SummerAire SBB may not stop if the warm air temperature exceeds 200°F and the oil burner does not shut down. This can happen due to blocked cold air return or closed warm air registers, which should be opened and cleared to allow proper airflow.

This answer is automatically generated

Summary of Contents for SummerAire SBB

  • Page 1 INSTALLATION and OPERATING INSTRUCTIONS SUMMERAIRE GAMME SMO INSTALLATION AND OWNER’S OPERATING INSTRUCTIONS SBB WOOD/OIL COMBINATION FURNACE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING YOUR SUMMERAIRE FURNACE. SAVE THESE INSTRUCTIONS FOR REFERENCE THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER AND WHERE REQUIRED BY LAW, A LICENCED TECHNICIAN.
  • Page 2: Installation Instructions

    Installation Instructions In all cases, local building codes should be observed. Duct Connection Furnace Is Shipped In Six Packages: The return air duct connection should be tight, so that the Furnace heat exchanger, complete with fire door. blower cannot draw air from he furnace room which can interfere with the combustion air supply.
  • Page 3 Thermostats: To Install Fire Brick: Drawing #2 Select a location which is representative of the average 1. Install 6 brick in floor of firebox (see layout) house temperature, usually the living room. The thermo- 2. Place bottom row of bricks (for fire box sides, front stats should be mounted on an inside wall, never where and back), making sure bricks are in brick plate they will be subjected to drafts (warm or cold), above a...
  • Page 4 Furnace Unit Fan & Limit Bracket Blower Unit Fan & Limit Hole location determined by holes provided Note: Do not attach “BX” Conduit to warm air plenum Damper motor and bracket Secondary Air Open link in chain Control Summeraire Model S.B.B.
  • Page 5 Fire Brick Layout and Installation Fire brick retaining angle (fits over top row of bricks) Stainless steel brick guard (secured inside fire door with two screws) Brick layout for floor of fire box chamber Note: Install first Summeraire Model S.B.B.
  • Page 6 Solid fuel relay Junction box Note: R8225B. Relay not required when damper motor is used Fan and limit must be in this location. (See drawing detail) Blower cabinet may be installed on either side of oil end Summeraire Model S.B.B.
  • Page 7 Drawing No. 4 15 5/8” 4” 14 1/4” Cut out for blower on desired side Corner points of cut-out are indicated on both side panels Damper motor and bracket Secondary Secondary Air control Air control Summeraire Model S.B.B.
  • Page 8 The foregoing warranty applies only where installation has been made in full accordance with Federal and Local This is the only warranty applicable to Summeraire Laws and Codes or ordinances applying to installation of Furnace.
  • Page 9 Owner’s Operating Instructions higher than room temperature. This will open the draft damper allowing combustion air into the furnace. Model SBB Light the paper and close the fire charging door. Important: These Entire Instructions Must Be Read When the kindling is burning well put in some hardwood...
  • Page 10 Furnace Maintenance and Care To charge or inspect solid fuel side with scrap wood, push up smoke baffle and secure with smoke baffle tool, over door in full open position. Do not operate with fire Establish a routine for the storage of fuel, care of the door open.
  • Page 11 What to do when your oil furnace fails to start Caution: 1. Raise your thermostat to 5°C (10°F) above the present If the warm air temperature exceeds 200°F without the oil room temperature. burner shutting down quickly open the warm air registers 2.
  • Page 12 Emergency Procedure Soot or Chimney Fire 1. Close damper door by unhooking chain. 2. Close fire door. 3. Do not remove flue pipe before fire is completely out. 4. Call the fire department. Run-A-Way Fire 1. Close damper door by unlocking chain. 2.
  • Page 13 Specifications for SBB Furnace B.T.U. 96000 12000 124000 137000 BONNET *NOZZLE .85 - 80° 1.00 - 80° 1.10 - 80° 1.20 - 80° SS/AR SS/AR SS/AR SS/AR COMBUSTION SA-1 SA-1 SA-1 SA-1 CHAMBER 2 - 12 X 24 2 - 12 X 24...
  • Page 14 Creosote - Important Woodburning Information Creosote is the tar-like substance that forms on the heat exchanger, flue pipe and chimney when burning wood. Wood combustion is never complete, a visible sign is smoke coming from your chimney. Wood when freshly cut can contain as much as 50% moisture, depending on the type.
  • Page 15 Summeraire Model S.B.B.