SummerAire SOM SERIES User Manual

Som series mul-t-poise warm air oil fired furnace

Advertisement

Quick Links

WARM AIR OIL FIRED FURNACE
ALL SOM SERIES FURNACES ARE AIR CONDITIONING READY !
THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND
WHERE REQUIRED BY LAW, A LICENSED TECHNICIAN
IF YOUR SUMMERAIRE SOM SERIES OIL FURNACE HAS BEEN INSTALLED USING THE
APPROVED SS2-C TJERNLUND SIDEWALL POWER VENTOR; IT IS YOUR
RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE,
______________________________
Installing Contractor
______________________________
Unit Model Number
USER MANUAL
SOM SERIES
MUL-T-POISE
Save These Instructions For Reference
NOTICE TO HOMEOWNER
NOTICE TO HOMEOWNER
SNOW, AND DEBRIS
FOR SERVICE CALL:
INSTALLATION INFORMATION
________________________________
Installation Date
Summeraire Mfg.
Peterborough, Ontario
K9J 7B1
_____________________________
Telephone Number
_____________________________
Unit Serial Number
OCT., 2007R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOM SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for SummerAire SOM SERIES

  • Page 1 WHERE REQUIRED BY LAW, A LICENSED TECHNICIAN NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SOM SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS2-C TJERNLUND SIDEWALL POWER VENTOR; IT IS YOUR RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE,...
  • Page 2 OPERATING INSTRUCTIONS CAUTION: NEVER BURN GARBAGE, REFUSE OR PAPER IN THE HEATING UNIT. NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE. IDENTIFY THE LOCATION OF YOUR BURNER / FURNACE POWER SWITCH OIL BURNER OPERATING INSTRUCTIONS • Use No 2 furnace oil ONLY • Do not use gasoline, crankcase oil, or any oil containing gasoline.
  • Page 3 • Make sure your “ Oil Burner “ power switch is in the “ ON “ position • If you hear a hum from the oil burner, and the motor has not started, press the reset button on the burner motor once only. • Blown fuse / “ tripped “ breaker in electrical panel • Thermostat may be set below room temperature. • Burner relay ( combustion control ) may have to be “ reset “ ( press reset once only ) • Oil valve may be closed. • Oil supply may be too low. • Blocked flue sensor “ tripped “ • If the oil burner fails to start or runs for only a few seconds, call a qualified service technician. FAN CONTROL – INFITEC Part No, DFS530S180 The Fan Control used on the Summeraire SOM series of furnaces is controlled by a “Timed Relay”. After Burner Ignition, the blower will start after 30 seconds. The blower turns “Off” or returns to “Constant Speed” 3 minutes after the Oil Burner shuts OFF. There is NO ADJUSTMENT on the “Timed Relay” DUAL AIR OPERATION This furnace is equipped with a dual ( two ) speed blower system which allows partial air distribution at all times. When the thermostat calls for Heat, the Oil Burner starts and the HIGH speed quickly distributes warm air throughout the home. When the HIGH SPEED stops, the “LOW” speed continues operating, circulating the air to even the temperature throughout the house. If the “LOW” speed feature is not required / desired, operate the small “rocker” switch located on the power junction box. MAINTENANCE...
  • Page 4 This furnace should never be operated without filters. A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season, or as required. Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace, are listed below. DO NOT SUBSTITUTE ! Note: Changing the type or size of filter used in your Summeraire furnace can seriously affect the operation of the furnace! AIR FILTER SPECIFICATIONS Filter size: SOM75-16” X 20” X 1” – CSA or ULC Certified/Approved - Type: Throw-away/disposable SOM95-16” X 20” X 1” – CSA or ULC Certified/Approved - Type: Throw-away/disposable SOM125-20“ X 25” X 1” – CSA or ULC Certified/Approved - Type:Through-away/disposable USE OF FILTERS OTHER THAN THOSE SPECIFIED ABOVE, CAN CAUSE DANGEROUS ELEVATION OF FURNACE TEMPERATURES –...
  • Page 5 NOTE: IF YOUR SUMMERAIRE FURNACE IS INSTALLED WITH A SS2-C TJERNLUND SIDEWALL POWER VENTOR. IT IS THE USERS / HOMEOWNERS RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE , SNOW AND DEBRIS !
  • Page 6 Laundromats, Beauty Salons, etc. 11. Summeraire Mfg. shall not be responsible for any failure due to water damage and/ or Acts of God. 12. No Air Conditioning or Heat pump coil may be installed on the return air side of this furnace.