SummerAire S150 Installation And Operating Instructions Manual

Add-on furnace

Advertisement

Installation and OPERATING
INSTRUCTIONS
S150
ADD-ON FURNACE
READ AND UNDERSTAND THESE INSTRUCTIONS
BEFORE OPERATING YOUR SUMMERAIRE FURNACE
SAVE THESE INSTRUCTIONS FOR REFERENCE
THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER
AND WHERE REQUIRED BY LAW, A LICENCED TECHNICIAN.
SUMMERAIRE MFG.
PETERBOROUGH, ONTARIO
FOR SERVICE CALL:
NAME : ____________________________________
ADDRESS : _________________________________
____________________________________________
TELEPHONE : _______________________________

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SummerAire S150

  • Page 1 INSTRUCTIONS S150 ADD-ON FURNACE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING YOUR SUMMERAIRE FURNACE SAVE THESE INSTRUCTIONS FOR REFERENCE THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER AND WHERE REQUIRED BY LAW, A LICENCED TECHNICIAN. SUMMERAIRE MFG.
  • Page 2: Installation Instructions

    Installation Instructions FIRED FURNACE. 9. If series method of interconnecting duct is used and The S-150 “Summeraire” Add-On wood burning furnaces the existing oil or gas furnace is equipped with plenum are assembled. Your installer will be required to do some mounted fan limit control, the divider panel which you wiring.
  • Page 3 S-150 casing. heat exchanger reaches this temperature. Draft at chimney should be between .05 and .08 inches water column. 6. The S-150 Summeraire add-on unit shall only be installed on a furnace duct system and chimney which The C.S.A. Certified Draft Regulator supplied must be are in good operating condition.
  • Page 4 You must give your customer both the Installation and Owner’s Operation Instructions and caution him as to the safety practices which he must comply with. Testing All “Summeraire” furnaces are factory tested to ensure reliability of welding; air streams tests have been conduct- ed to minimize primary surface temperatures and ensure efficient air circulation.
  • Page 5 Warm Air Supply Plenum Divider NOTE: Minimum Plenum height for Minimum Radius 6” existing Oil Furnace 26” Summeraire Energy Saver Model S150 Existing Furnace (OIL or GAS) Floor Level Minimum Duct Size 240 sq. ins. “SERIES” FLOW INSTALLATION METHOD...
  • Page 6 26” Minimum Plenum Height Minimum Radius 6” Existing Summeraire OIL or GAS Model S150 Furnace Energy Saver Floor Level Minimum Duct Size 240 sq. in. INLINE FLOW INSTALLATION METHOD...
  • Page 7 WIRING DIAGRAM FOR ADD - ON TO GAS FURNACE ONLY NOTE: Remove existing thermostat wires. Hook these wires to terminals. W & R on Isolating relay. Run a thermostat wire from TH & TH on Gas Valve S-150 Summeraire ADD - ON Furnace...
  • Page 9 Finally We stress that it is your obligation to see that: 1. Owner receives - A) “Owner’s Operating Instructions” B) This set of Installation Instructions 2. That installation is made in accordance with C.S.A. Installation Standard B 365 or the National Building Code OR Local Codes and regulations.
  • Page 10 S-150 “Summeraire” Add-on Furnace Keep fire door closed and maintain all seals in good condition. Read these instructions carefully and completely before firing your unit. They spell out clearly your responsibili- Make sure adequate combustion air is provided in furnace ties in operating the unit. This furnace has been designed area. to give you safe and efficient operation for years when properly maintained and cleaned. The S-150 Add-On is not to be used with an automatic stoker.
  • Page 11 cleaned by your heating contractor as soon after the end In a few days you will establish the basic recharging of the heating season as possible. period for your specific application. Chimney cleaning should be done whenever any signifi- It is better to build small intense fires than building large cant soot and creosote build up is noticed. A visual inspec- smoldering fires as they reduce creosote build-up.
  • Page 12 Emergency Procedure output required. Spring and fall require frequent small charges. A small intense fire produces less creosote. Soot or Chimney Fire Short flue pipe runs help to keep the gases above the dew 1. Close damper door by unhooking chain. point. 2. Close fire door. The interior chimney holds and retains heat longer result- 3. Do not remove flue pipe before fire is completely out. ing in less condensation than the exterior chimney. 4. Call the fire department.
  • Page 13 The following forms part of this warranty and is intended to elaborate on specific points of our Limited Warranty: Summeraire Mfg. warrants, on a limited basis, this fur- Warranty on above model will be denied as per the nace to be free from defects in manufacturing as follows:...
  • Page 14 Summeraire Mfg., 2040 Fisher Drive, Peterborough, Ontario, Canada, K9J 6X6. F-S150-INSMAN-EN-REV6...