INSTALLATION AND OWNER'S OPERATING INSTRUCTIONS
SWO COAL/WOOD/OIL COMBINATION FURNACE
READ
BEFORE OPERATING YOUR SUMMERAIRE FURNACE.
THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER
AND WHERE REQUIRED BY LAW, A LICENCED TECHNICIAN.
INSTALLATION and OPERATING
INSTRUCTIONS
SUMMERAIRE
GAMME SMO
AND UNDERSTAND THESE INSTRUCTIONS
SAVE THESE INSTRUCTIONS FOR REFERENCE
SUMMERAIRE MFG.
PETERBOROUGH, ONTARIO
FOR
SERVICE CALL:
NAME : __________________________
ADDRESS : ______________________
__________________________________
TELEPHONE : ____________________
SWO

Advertisement

loading
Need help?

Need help?

Do you have a question about the SWO and is the answer not in the manual?

Questions and answers

Summary of Contents for SummerAire SWO

  • Page 1 INSTALLATION and OPERATING INSTRUCTIONS SUMMERAIRE GAMME SMO INSTALLATION AND OWNER’S OPERATING INSTRUCTIONS SWO COAL/WOOD/OIL COMBINATION FURNACE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING YOUR SUMMERAIRE FURNACE. SAVE THESE INSTRUCTIONS FOR REFERENCE THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER AND WHERE REQUIRED BY LAW, A LICENCED TECHNICIAN.
  • Page 2 Installation Instructions Installation of the combination furnace Furnace Is Shipped In Six Packages: Location Furnace heat exchanger, complete with fire and sash Refer to C.S.A. B139 “CODE FOR INSTALLATION OF OIL pit doors, ash pan, grate bars, burner mounting plate, BURNER EQUIPMENT”...
  • Page 3 Installation of the Combination Furnace Assemble the blower section by tilting it, so the flames fit into the heat exchanger section. Screw both sections (continued) together. Chimney and Flue Pipe To Mount The Burner: .03 to .05 inches WC at the flue connection of the fur- burner is flush mounted with three positioning bolts nace, and .01 to .03 inches draft over the fire.
  • Page 4 Drawing No. 1 Round holes for secondary air Secondary Air Control Damper motor and bracket Secondary Air Control Side Open link in chain Summeraire Model S.W.O.
  • Page 5 Drawing No. 2 Fire Brick Layout and Installation Fire brick retaining angle (fits over top row of bricks) Stainless steel brick guard (secured inside fire door with two screws) Summeraire Model S.W.O.
  • Page 6 Wire harness 6” min. from flue Straight connector Solid fuel relay Cable clips Junction box Straight connection Front plate Wire harness (4” Min. from Front plate) Straight connector Oil burner Oil relay Junction box 12” 7” Heat Exchanger space panel Summeraire Model S.W.O.
  • Page 7 Summeraire Model S.W.O. Wiring Diagram...
  • Page 8 Specifications for SWO Furnaces MODEL SWO-124-2 SWO-124-3 SWO - 151 SWO - 169 B.T.U. 112000 124000 135000 140000 151000 169000 BONNET *NOZZLE 1.00 - 70°NS 1.10 - 70°NS 1.20 - 70°NS 1.25 - 70°NS 1.35 - 70°NS 1.25 - 70°NS...
  • Page 9 Installation of the Combination Furnace (cont’d) Installation Tips *Minimum Duct sizes Model Supply Air Return Air SWO 124 220 Sq. In. 250 Sq. In. SWO 152 240 Sq. In. 280 Sq. In. SWO 169 260 Sq. In. 300 Sq. In.
  • Page 10 *From year 10 and over 100% This is the only warranty applicable to Summeraire The foregoing warranty applies only where installation has been made in full accordance with Federal and Local Furnace.
  • Page 11 Owner’s Operating Instructions Light the paper and close the fire charging door. When the kindling is burning well put in some hardwood Important: These Entire Instructions Must Be and allow this to begin burning. Read Add hardwood; These entire instructions must be read to ensure the best do not fill the firebox above the door sill possible operation and safest use of the furnace.
  • Page 12 Furnace Maintenance and Care PREMATURE FURNACE FAILURE, A FIRE HAZARD AND VOID WARRANTY. Establish a routine for the storage of fuel, care of the appliance, and firing techniques. Check daily for creosote Adjustment of the solid fuel air damper should never build up until experience shows how often cleaning is exceed 1/2 inch open.
  • Page 13 To Use Oil Side: Safety There are two thermostats, one to control the solid fuel Whenever a loading door is opened, it always should be section and one to control the oil operating section. Set cracked slightly before full opening to allow oxygen to solid fuel thermostat at its lowest setting to prevent solid enter and burn any combustible gases that are present.
  • Page 14 Coal Burning Instructions exactly; and coal must not be built up above the door sill; ash deposits must be kept off grates and the ash in the ash pan must be allowed to build up under the grates. The flue draft must be -.05” W.C.
  • Page 15 c) Insert a duct thermometer to its highest warm air duct Power Failure at a point 12 inches downstream from the furnace plenum. If the limit control is functioning correctly the 1. Close damper door by unhooking chain. burner will shut off on high limit before the thermome- ter reads 200°F.
  • Page 16 Creosote - Important Woodburning Information Creosote is the tar-like substance that forms on the heat exchanger, flue pipe and chimney when burning wood. Wood combustion is never complete, a visible sign is smoke coming from your chimney. Wood when freshly cut can contain as much as 50% moisture, depending on the type.