9. Fill engine crankcase with correct John Deere engine
oil through rocker arm cover opening (A). (See
DIESEL ENGINE OIL in Fuels, Lubricants, and
Coolant Section for determining correct engine oil.)
To determine the correct oil fill quantity for your engine,
see ENGINE CRANKCASE OIL FILL QUANTITIES in
the Specifications Section of this manual.
IMPORTANT: Immediately after completing any
oil change, crank engine for 30 seconds
without permitting engine to start. This will
help insure adequate lubrication to engine
components before engine starts.
NOTE: Crankcase oil capacity may vary slightly.
ALWAYS fill crankcase within crosshatch marks
on dipstick. DO NOT overfill.
10. Start engine and run to check for possible leaks.
11. Stop engine and check oil level after 10 minutes. Oil
level reading should be within crosshatch on dipstick.

Servicing Fire Extinguisher

A fire extinguisher (A) is available from your authorized
servicing dealer or engine distributor.
Read and follow the instructions which are packaged with
it. The extinguisher should be inspected at least every
250 hours of engine operation or every 6 months. Once
extinguisher is operated, no matter how long, it must be
recharged. Keep record of inspections on the tag which
comes with the extinguisher instruction booklet.
Lubrication & Maintenance/250 Hour/6 Month
OM-C3 | 12/6 | 32
A—Rocker Arm Cover Oil Filler
Opening
Fire Extinguisher
RG19661,00003D4 -19-28FEB13-3/3