ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS:

In order to prevent potential electrical shock and injury, the following electrical safety precautions and symbols
should be followed at all times!
In case of a malfunction or breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This tool is equipped with an electric cord having an
equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
• Do not modify the plug provided – if it will not fit the outlet; have the proper outlet installed by a
qualified electrician
• Improper connections of the equipment-grounding conductor can result in a risk of electric shock.
The equipment-grounding conductor is the insulated conductor that has an outer surface that is
green, with or without yellow stripes. If repair or replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding conductor to a live terminal
• Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded
• Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that
accept the tool's plug
• Repair or replace a damaged or worn cord immediately
This tool is intended for use on a circuit that has an outlet that looks like the one shown in Sketch A
of Figure 1. The tool has a grounding plug that looks like the plug illustrated in Sketch A of FIGURE
1. A temporary adapter, which looks like the adapter illustrated in sketches B and C, may be used to
Metal Screw
Cover of Grounded
Outlet Box
(A)
Grounding
Pin
ADAPTER
Grounding
(C)
Grounding
Means
Pin
FIGURE 1
To reduce the risk of electrocution, keep all connections dry and off the ground.
A Ground Fault Circuit Interrupter (GFCI) should be provided on the circuit(s) or outlet(s) to be used
for the Tile Saw. Receptacles are available having built-in GFCI protections and may be used for
this measure of safety.
When using an extension cord, the GFCI should be installed closest to the power source, followed
by the extension cord and lastly, the saw.
MK-2000
connect this plug to a 2-pole receptacle as shown in Sketch B, if a
properly grounded outlet is not available. The temporary adapter
should be used only until a properly grounded outlet can be
installed by a qualified electrician. The green-colored rigid ear,
lug, and the like, extending from the adapter, must be connected
(B)
to a permanent ground such as a properly grounded outlet box.
NOTE: Use of a temporary adapter is not permitted in Canada.
(D)
Revision 03/05, Effective Date March 21, 2005