Pump Control Connections - Takagi 710 Installation Manual And Owner's Manual

Gas tankless on-demand water heater
Table of Contents

Advertisement

The water heater can be used to control a recirculation pump. Proper pump control helps to
preserve the life of the system and saves energy as well.
The water heater pump control port is a "normally-open dry contact", and therefore needs
additional components to properly control a recirculation pump. To control a recirculation pump,
connect the pump to the "Pump connector" in the water heater as shown in the diagram below.
(In a multi-unit system, connect the pump ONLY to the "PARENT" unit.) The pump is to be
connected using suitable relays shown in the diagram below.
Please make sure the relays are properly rated for the recirculation pump.
Using the water heater's internal thermistors as a temperature control, the recirculation pump
will only turn on when recirculation is needed.
CAUTION: In a multi-unit system, the pump must be connected to the
"Pump" connector in the "PARENT" unit only. If the pump is connected to
any of the "CHILD" units, the pump will not work.
Connect to this "Pump connector".

PUMP CONTROL CONNECTIONS

These components are NOT included with
water heater and are external to the unit.
They must be acquired separately.
Power supply for relay
- 21 -
Power supply for pump
120 VAC
220 VAC etc
120 VAC
220 VAC etc
for relay
Thermal relay
Recirculation
pump