The  T‐H2‐DV/T‐H2‐OS  can  be  used  to  control  a  recirculation  pump.  Proper  pump  control  helps  to 
preserve the life of the system and saves energy as well: The T‐H2‐DV/T‐H2‐OS pump control port is a 
"normally  open  dry  contact",  and  therefore  needs  additional  components  to  properly  control  a 
recirculation pump. To control a recirculation pump, connect the pump to the "Pump connector" in the 
T‐H2‐DV/T‐H2‐OS as shown in the diagram below. (In an Easy‐Link system, connect the pump ONLY to 
the "MASTER" unit.) The pump is to be connected using suitable relays shown in the diagram below.  
Please make sure the relays are properly rated for the recirculation pump.  
Using the T‐H2‐DV/T‐H2‐OS's internal thermistors as a temperature control, the recirculation pump will 
only turn on when recirculation is needed. 
 
 
 
 
In an Easy‐Link system, the pump must be connected to the "Pump connector" in 
the "MASTER unit" only. If the pump is connected to any of the "SLAVE units", the 
pump will not work. 
CAUTION 
PUMP CONTROL CONNECTION 
Connect to this "Pump connector". 
Thermal  
relay 
These components are NOT included with the T‐H2‐DV/T‐H2‐OS 
and are external to the unit.  They must be acquired separately. 
 
Power supply 
for pump 
AC120V 
AC220V etc 
AC120V 
AC220V etc 
for relay 
25
 
Page
Installation 
Power supply 
 for relay 