6. Troubleshooting
Code Faults
D03
OUTL S.B FAIL.
D04
OUTL S.C FAIL.
D05
OUTSI.S.FAIL.
D07
AUX.SENS.FAIL.
D09
DHW S.FAILURE
D11
ROOM S.A FAIL.
D12
ROOM S.B FAIL.
D13
ROOM S.C FAIL.
D14
MC COM.FAIL
D15
ST.TANK S.FAIL
D16
SWIM.P.B. S.FAIL
D16
SWIM.P.C. S.FAIL
D17
DHW 2 S.FAIL
37
Cause
Description
of the
fault
SCU
Circuit B flow sensor fault
Circuit C flow sensor fault
Remarks:
The circuit pump is running.
The 3-way valve motor on the circuit
is no longer powered and can be
adjusted manually.
SCU
Outside temperature sensor fault
Remarks:
The boiler operates on BOILER
MAX temperature.
The valve setting is no longer
ensured but monitoring the
maximum temperature of the circuit
after the valve is ensured.
Valves may be manually operated.
Reheating the domestic hot water
remains ensured.
SCU
Auxiliary sensor fault
SCU
Domestic hot water sensor fault
Remarks:
Heating of domestic hot water is no
longer ensured.
The load pump operates.
The load temperature of the dhw
tank is the same as the boiler.
SCU
A room temperature sensor fault
B room temperature sensor fault
C room temperature sensor fault
Note:
The circuit concerned operates
without any influence from the room
sensor.
SCU
Communication failure between the
SCU PCB and the boiler radio
module
SCU
Storage tank sensor fault
Note:
The hot water storage tank
reheating operation is no longer
assured.
SCU
Swimming pool sensor fault circuit
B
Swimming pool sensor fault circuit
C
Note:
Swimming pool reheating is always
done during the circuit's comfort
period.
SCU
Sensor fault tank 2
MCA 15 - MCA 25 MCA 25/28 MI
Checking / solution
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Check the link and the connectors
4
Boiler module failure
Change the boiler module
4
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
23/08/2011 - 300024159-001-B