DeDietrich MCA 15 User Manual page 33

Wall-hung gas condensing boilers
Hide thumbs Also See for MCA 15:
Table of Contents

Advertisement

MCA 15 - MCA 25 MCA 25/28 MI
Code Messages
B08
BL.RL OPEN
B09
BL.INV. L/N
B10
BL.BL INPUT
B11
OPEN
B13
BL. PCU COM
B14
BL.WATER MIS.
B15
BL.GAS PRESS
B16
BL.BAD SU
B17
BL.PCU ERROR
B18
BL.BAD PSU
B19
BL.NO CONFIG
B21
BL. COM SU
B22
BL.FLAME LOS
B25
BL.SU ERROR
23/08/2011 - 300024159-001-B
Description
The RL inlet on the PCU PCB
terminal block is open
Contact the professional who takes care of maintenance of the appliance
4
The BL inlet on the PCU PCB
terminal block is open
Communication error with the
SCU PCB
The water pressure is lower than
0,8 bar
Gas pressure too low
The SU PCB is not recognised
The parameters saved on the
PCU PCB are impaired
The PSU PCB is not recognised
The boiler has not been
configured
Communication error between
the PCU and SU PCBs
No flame during operation
Internal error on the SU PCB
Checking / solution
Parameter error
Contact the professional who takes care of maintenance of
4
the appliance
Bad connection
Contact the professional who takes care of maintenance of
4
the appliance
The contact connected to the BL inlet is open
Contact the professional who takes care of maintenance of
4
the appliance
Parameter error
Contact the professional who takes care of maintenance of
4
the appliance
Bad connection
Contact the professional who takes care of maintenance of
4
the appliance
Bad connection
Contact the professional who takes care of maintenance of
4
the appliance
SCU PCB not installed in the boiler
Contact the professional who takes care of maintenance of
4
the appliance
Not enough water in the circuit
Top up the installation with water
4
Incorrect setting of the gas pressure switch on the SCU PCB
Check that the gas valve is fully opened
4
Contact the professional who takes care of maintenance of
4
the appliance
Wrong SU PCB for this boiler
Contact the professional who takes care of maintenance of
4
the appliance
Parameter error on the PCU PCB
Contact the professional who takes care of maintenance of
4
the appliance
Wrong PSU PCB for this boiler
Contact the professional who takes care of maintenance of
4
the appliance
The PSU PCB has been changed
Contact the professional who takes care of maintenance of
4
the appliance
Bad connection
Contact the professional who takes care of maintenance of
4
the appliance
No ionization current
Check that the gas valve is fully opened
4
Contact the professional who takes care of maintenance of
4
the appliance
Contact the professional who takes care of maintenance of
4
the appliance
6. Troubleshooting