General Description - continued
of hydraulics states that if you halve the speed, the power reduces by 8 times. The multiple speeds
offered by the Badu EcoM3 enables it to run slower and consume less energy but still have the ability to
run at full speed if required.
The Badu EcoM3 operates at a maximum system flow of 100 gallons per minute (GPM).
This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600, 2600, and 3450 RPM.
This allows you to select the most appropriate speed for your application. The Badu EcoM3 was designed
to meet the needs of today's more environmentally friendly consumer. The pump parts are made of 100%
recyclable "environment friendly" plastic. The axial flux brushless-DC motor, has a significant reduction in
greenhouse gas emissions, saving greater than 2 tonne CO
savings per year.
Figure 1
3

Installation Information

Preparation Guide

1. Upon receipt of the pump, check the carton for damage. Open the carton and check the pump for
concealed damage, such as cracks, dents, or a bent base. If damage is found, contact the shipper or
distributor where the pump was purchased.
2. Inspect the contents of the carton and verify that all parts are included. See Section 7, Parts List and
Exploded View.
per year. Lower noise reduction, and energy
2
The Badu EcoM3 control panel provides manual speed con-
trols for the pump. There are three preset speed buttons that
can be selected low, medium, and high.
Controls and LEDs
1. low, med, and high button/LED: Press one of the buttons
to select the desired preset pump speed. The pump preset
speeds are: low (1600 RPM), med (2600 RPM), and high
(3450 RPM). The button green LED is on when the selected
button is pressed.
2. Power LED: This green LED light is on when the Badu
EcoM3 pump is powered up.
3. Error LED: This red LED is on whenever an error has oc-
curred.
4. STOP button: Press to turn the pump off.
WARNING: STOP button will turn off the pump but voltage is
still present. Always turn OFF the breaker before servicing.