MCR 24/28 BIC
Parameter Description
Flow temperature
p1
Domestic hot water temperature 40 to 65 °C
p2
Heating / DHW mode
p3
ECO mode
p4
Anticipation resistance
p5
Display screen
p6
170513 - 300024112-001-01
4.2.5.
1. Press the N key.
The symbol N and the current temperature are displayed.
2. Press the key [-] several times until the value 0ff is displayed.
3. To confirm the new value, press the key S .
The symbol T appears.
("

"KK
T000142-A
4.2.6.
Adjustment range
20 to 85 °C
0 = Heating deactivated (C) / DHW deactivated (T)
1 = Heating activated (D) / DHW activated (N)
2 = Heating activated (D) / DHW deactivated (T)
3 = Heating deactivated (C) / DHW activated (N)
0 = Comfort mode
1 = Energy-saving mode
2 = Management using a programmable thermostat
0 = No anticipation resistance for the ON/OFF thermostat
1 = Anticipation resistance for the ON/OFF thermostat
0 = The screen stays off
1 = The screen stays on
2 = The screen switches off automatically after 3 minutes

Stopping domestic hot water production

It also possible to modify this setting using the parameter
p3. ¼See chapter: "Other settings", page 16.

Other settings

4. Operating the appliance
Factory setting
75 °C
60 °C
1
0
0
2
16