TROUBLE SHOOTING

Problem
Possible Cause/Solution
Smoke
There may not be enough draft in the chimney (<0.06" WC (<16
coming out of
Pascals)). Check for an obstruction.
the door
Soot on the
Take care that the stove is warmed up sufficiently before closing the
glass
door.
The stove is
Check the door gaskets first and replace if needed. The chimney could
burning too
also be too high and thus create too much draft (>0.09" WC (>22
quickly
Pascals)). A damper may be needed.
The stove is
It could be due to too little air getting to the stove. Check that you're not
burning too
running exhaust fans (kitchen/bath), the chimney is not blocked, or there
slowly
is a leak between the chimney, the stovepipe, and the stove.
If the problem continues or other conditions, we recommend that you contact your chimney
sweep or your dealer.
If you should experience a chimney fire, quickly close all doors, dampers, vents, and call
you local fire department. Don't use water to extinguish the fire.

Warranty

We offer a 5-year warranty on your RAIS stove, which covers any defect in material or
workmanship. It does not cover damage from misuse or neglect. The glass, gaskets,
firebrick and vermiculite stone liners are not covered.