in order to insure proper reinstallation.
4.
Remove the power cord ground wire from
the oven chassis. Note that this screw is
a machine screw with fine threads. Be
sure to mark this screw for proper rein-
stallation.
5.
Disconnect the two wire connectors from
the fuse holder.
6.
Disconnect the two red wires from the vent
motor capacitor.
VENT MOTOR
CAPACITOR
CONNECTOR
PLUG
GROUND
WIRE
6.
Disconnect the two power cord connec-
tor plugs and remove the power cord.
7.
Disconnect the upper halogen blower pair
connector plugs (one blue and one clear/
white).
8.
Disconnect the humidity sensor wire from
the smart board (red connector plug).
9.
Disconnect the oven cavity T.C.O. quick
disconnect plug (2 pin yellow quick dis-
connect plug) located in the same prox-
imity as the humidity sensor wires.
10.
Note the wire retainer clip in
CAUTION
the following illustration. This clip holds
the oven cavity thermistor wires. Be sure
to remove these wires from this clip prior
to proceeding with the removal of the up-
per halogen blower/lamp assembly. If you
do not remove these wires you can
damage or break them when removing
CAPACITOR
H.V. WIRES
FUSE
HOLDER
– 40 –
the blower/lamp assembly. They must
be removed in order to remove the blower/
lamp assembly.
WIRE
RETAINER
CLIP
UPPER
HALOGEN
BLOWER
PLUG
BOTTOM SIDE OF UPPER HALOGEN
BLOWER/LAMP ASSEMBLY
11. Remove the 12 screws securing the
blower/lamp assembly to the oven chas-
sis.
A
A
A
B
B
B
UPPER HALOGEN
BLOWER/LAMP ASSEMBLY
REMOVAL
OVEN
CAVITY
T.C.O.
PLUG
UPPER
HALOGEN
HUMIDITY
PLUGS
SENSOR
PLUG
A
A
A
A
B
A
A
THERMISTOR
LEADS

Hide quick links:

Advertisement

Table of Contents
loading