The following is a summary of interoperability mode behavior on B-series switches.
The Msplmgmtdeactivate command must be run prior to connecting it to any C-series, or else
the fabric will be segmented.
Zoning can only be defined with port WWNs. Port numbers and NWWNs are not valid fields to
zone by.
To manage zoning administration from a B-series switch, all B-series must be interconnected to
facilitate the forwarding of the inactive zone configuration also.
Domain IDs are restricted to the range 97–127 to accommodate nominal restriction by some
vendors.
Private loop targets will automatically be registered in the fabric using translative mode.
Fabric Watch is restricted to Brocade switches only.
The full zoneset (configuration) is distributed to all switches in the fabric, but C-series accepts only
active zoneset.
Disabled services:
• Secure Fabric OS is not supported.
• Management Server is not supported
• Virtual Channels are disabled.
• Quickloop is disabled.
• Domain/port representation in zones is not valid.
• Trunking between B-series is not supported.
Merging zones-examples
This example depicts the creation of three zones (vz1, vz2, and vz3) on one of the C-series switches;
and then the verification that these zones propagate to all the C-series and B-series switches in the
interoperating fabric.
MDS9509# conf t
Enter configuration commands, one per line.
MDS9509(config)# zone name vz1 vsan 1
MDS9509(config-zone)# member pwwn 50:06:01:60:88:02:90:cb
MDS9509(config-zone)# member pwwn 10:00:00:00:c9:24:3d:90
MDS9509(config-zone)# exit
MDS9509(config)#
MDS9509(config)# zone name vz2 vsan 1
MDS9509(config-zone)#
MDS9509(config-zone)# member pwwn 10:00:00:00:c9:24:3f:75
MDS9509(config-zone)# member pwwn 21:00:00:20:37:a7:ca:b7
MDS9509(config-zone)# member pwwn 21:00:00:20:37:a7:c7:e0
MDS9509(config-zone)# member pwwn 21:00:00:20:37:a7:c7:df
MDS9509(config-zone)#
MDS9509(config-zone)# exit
MDS9509(config)#
MDS9509(config)# zone name vz3 vsan 1
MDS9509(config-zone)#
MDS9509(config-zone)# member pwwn 10:00:00:e0:69:f0:43:9f
12
End with CNTL/Z.