Programming The Softener (Model M34) Customizing Features / Options - Morton System Saver M20 Installation And Operation Manual

Water softener
Table of Contents

Advertisement

Programming the Water Softener
RECHARGE button
When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display. Then,
"12:00 PM" and the words "SET TIME" begin to flash.
NOTE: If "- - - -" shows in the display, press the
q
UP or
DOWN button until the model code
("o20" for Model M20, "o27" for Model M27,
"o30" for Model M30 or "o34" for Model M34)
shows in the display. Then, press the
SELECT button to set, and change to the
flashing "SET TIME" display.
Step 1. Set Time of Day
If the words "SET TIME" do not show in the display,
press the SELECT button until they do.
q
1. Press the
UP or
DOWN buttons to set the
present time. Up moves the display ahead; down
sets the time back. Be sure AM or PM is correct.
NOTE: Press buttons and quickly release to slowly
advance the display. Hold the buttons down
for fast advance.
Step 2. Set Water Hardness Number
1. Press the SELECT button once again to display a
flashing "25" and the words "SET HARDNESS".
q
2. Press the
UP or
DOWN buttons to set your
water's hardness number.
16
Display
SELECT button
FIG. 28
Morton
System Saver
Installation & Operation Manual
®
®
Low Salt LED Indicator
UP button
DOWN button
NOTE: If your water supply contains iron, compen-
sate for it by adding to the water hardness
number. For example, assume your water is
20 gpg hard and contains 2 ppm iron. Add 5
to the hardness number for each 1 ppm of
iron. In this example, you would use 30 for
your hardness number.
2 ppm iron x 5 = 10 +10
(times)
Step 3. Set Recharge (Regeneration)
Time
Your demand water softener will automatically regener-
ate when it needs to, based on water usage. The time
of day that the automatic recharge cycle begins may
be changed as follows:
1. Press the SELECT button once again to display a
flashing "2:00AM" and the words "SET RECHARGE
TIME". This is a good time for the recharge to start
in most households, because water is not in use.
2. If you want to change the recharge start time,
q
press the
UP or
DOWN buttons until the
desired time shows. Be sure AM or PM is correct.
(Model M34)
FIG. 29
FIG. 30
20 gpg hardness
30 HARDNESS NUMBER
FIG. 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

System saver m34System saver m27System saver m30Mc30

Table of Contents