Automatic Electronic Diagnostics
This water softener has a self-diagnostic function for
the electrical system (except input power and/or water
meter). The water softener monitors electronic com-
ponents and circuits for correct operation. If a mal-
function occurs, an error code appears in the display.
While an error code appears in the display, all buttons
are inoperable except the SELECT button. SELECT
remains operational so the service person can per-
form the Manual Advance Diagnostics, see below, to
further isolate the problem.
Procedure for removing error code from dis-
play:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 8 minutes. The error code will return if
the problem was not corrected.
Manual Advance Diagnostics
Use the following procedures to advance the water
softener through the regeneration cycles to check
operation.
Remove the top cover to expose the valve and ob-
serve cam and switch operation during valve rotation.
1. Press and hold SELECT for 3 seconds until "000"
shows in the display, then release.
2. The 3 digits indicate water meter operation as fol-
lows:
000 (steady) = Soft water not in use, and no flow
through the meter.
Open a nearby soft water faucet.
000 to 199 (continual) = Repeats for each gallon
3. The letter "P" and a dash (or dashes) indicate
POSITION switch operation (See Figure 45). If the

Troubleshooting

FIG. 44
of water passing through
the meter.
Morton
System Saver
®
letter appears, the switch is closed. If the dash
shows, the switch is open.
Water
Switch
Meter
4. Use the RECHARGE button to manually advance
the valve into each cycle and check correct switch
operation.
NOTE: Be sure water is in contact with the salt, and
not separated by a salt bridge (See "Breaking
A Salt Bridge" section).
5. While in this diagnostic screen, the following infor-
mation is available and may be beneficial for vari-
ous reasons. This information is retained by the
computer from the first time electrical power is
applied to the electronic controller.
a. Press the
days this electronic control has had electrical
power applied.
b. Press the
of regenerations initiated by this electronic con-
trol since the code number was entered.
6. Press and hold the SELECT button until the model
code ("o20" for Model M20, "o27" for Model M27,
"o30" for Model M30 or "o34" for Model M34)
shows in the display. This code identifies the sof-
tener model. If an incorrect model code is dis-
played, the softener will operate on incorrect con-
figuration data.
7. To change the code number, press the
q
DOWN button until the correct code shows.
8. To return to the present time display, press the
SELECT button.
Installation & Operation Manual
®
UP button to display the number of
q
DOWN button to display the number
FIG. 45
FIG. 46
UP or
21