Programming the Water Softener

RECHARGE button
When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display. Then,
"12:00 PM" and the words "PRESENT TIME" begin to
flash.
NOTE: If "- - - -" shows in the display, press the
q
or
DOWN button until the model code
("o20" for Model M20, "o27" for Model M27,
"o30" for Model M30 or "o34" for Model M34)
shows in the display. Then, press the
SELECT button to set, and change to the
flashing "PRESENT TIME" display.
Step 1. Set Time of Day
If the words "PRESENT TIME" do not show in the dis-
play, press the SELECT button until they do.
q
1. Press the
UP or
DOWN buttons to set the
present time. Up moves the display ahead; down
sets the time back. Be sure AM or PM is correct.
NOTE: Press buttons and quickly release to slowly
advance the display. Hold the buttons down
for fast advance.
(Models M20, M27 & M30)
Display
UP
FIG. 16
Morton
System Saver
Installation & Operation Manual
®
®
UP button
DOWN button
SELECT button
Step 2. Set Water Hardness Number
1. Press the SELECT button once again to display a
flashing "25" and the word "HARDNESS".
q
2. Press the
UP or
DOWN buttons to set your
water's hardness number.
NOTE: If your water supply contains iron, compen-
sate for it by adding to the water hardness
number. For example, assume your water is
20 gpg hard and contains 2 ppm iron. Add 5
to the hardness number for each 1 ppm of
iron. In this example, you would use 30 for
your hardness number.
2 ppm iron x 5 = 10 +10
(times)
FIG. 17
FIG. 18
20 gpg hardness
30 HARDNESS NUMBER