Platinum 2100 H Installation And User Manual page 22

Hide thumbs Also See for 2100 H:
Table of Contents

Advertisement

Installation
+
P1
N1
Fit protective caps to plug connectors that are not used on the inverter.
22
+
P2
P3
N2
N3
1. Fit original Multi-Contact MC4
connectors to each string of the DC
voltage cable. Make sure that the
polarity is correct here.
2. Take off the protective caps from the
required DC voltage connections.
– String 1: Connections N1 and P1
– String 2: Connections N2 and P2
– String 3: Connections N3 and P3
– (N = negative, P = positive)
3. Connect the prepared DC voltage
connectors to the DC voltage
connections. In the process, make
sure that the connectors lock in place
correctly.
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H