MSC-A07WV -
E1
MSC-A09WV -
E1

INDOOR UNIT

Indoor coil
Indoor
thermistor
heat
RT12
exchanger
Room temperature
thermistor
RT11
MSC-A12WV -
E1
INDOOR UNIT
Indoor coil
Indoor
thermistor
heat
exchanger
RT12
Room temperature
thermistor
RT11
Refrigerant pipe [ 9.52
(with heat insulator)
Stop valve
(with service
port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [6.35
(with heat insulator)
Refrigerant pipe [12.7
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [6.35
(with heat insulator)
4-way valve
Muffler
Compressor
Capillary tube
[3.0x[1.6x350(MUH-A07WV)
[3.0x[1.6x600(MUH-A09WV)
Check valve
Strainer
Capillary tube
[3.0x[1.4x1050(MUH-A07WV)
[3.0x[1.4x1300(MUH-A09WV)
4-way valve
Muffler
Compressor
Capillary tube
[3.0x[1.6x1350
Strainer
Check
valve
33
MUH-A07WV -
MUH-A09WV -
OUTDOOR UNIT
Defrost
thermistor
Outdoor
RT61
heat
exchanger
Capillary tube
[3.0x[1.4x800(2 pcs)
(MUH-A07WV)
[3.0x[1.4x500(2 pcs)
(MUH-A09WV)
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
MUH-A12WV -
OUTDOOR UNIT
Defrost
Outdoor
thermistor
heat
RT61
exchanger
Capillary tube
[3.0x[1.4x500(2pcs)
Capillary tube
[3.0x[1.6x400
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating