Cool Mode Of "I Feel Control"; Dry Mode Of "I Feel Control"; Heat Mode Of "I Feel Control" Muh-A07/A09/A12Wv; The Initial Set Temperature Is Decided By The Initial Room Temperature - Mitsubishi Electric MSC-A07WV Service Manual

Split-type, air conditioners split-type, heat pump air conditioners
Hide thumbs Also See for MSC-A07WV:
Table of Contents

Advertisement

(4) The initial set temperature is decided by the initial room temperature.

Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
1 When the system is restarted with the remote controller, the system operates with the previous set temperature regard-
less of the room temperature at restart.
(5) TEMPERATURES buttons
In "I FEEL CONTROL" (
In addition, set temperature can be controlled by TOO WARM or TOO COOL buttons when you feel too cool or too
warm. Each time the TOO WARM or TOO COOL button is pressed, the indoor unit receives the signal and emits a beep
tone.
Fuzzy control
When the TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, considering
the room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user's preference to heat or
cool. So this is called "Fuzzy control", and works only in "I FEEL CONTROL" mode.
In DRY mode of "I FEEL CONTROL", the set temperature doesn't change.
TOO
COOL
... To raise the set temperature 1~2 degrees(°C)
TOO
WARM
... To lower the set temperature 1~2 degrees(°C)

11-5-1. COOL mode of "I FEEL CONTROL"

1. Thermostat control
Thermostat control is as same as COOL OPERATION.(11-1.1.)
2. Indoor fan speed control
Indoor fan speed control is as same as COOL OPERATION.(11-1.2.)
3. Coil frost prevention
Coil frost prevention is as same as COOL OPERATION.(11-1.3.)

11-5-2. DRY mode of "I FEEL CONTROL"

1. Thermostat control
Thermostat control is as same as DRY OPERATION.(11-2.1.)
2. Indoor fan speed control
Indoor fan speed control is as same as DRY OPERATION.(11-2.2.)
3. The operation of the compressor and indoor/outdoor fan
The operation of the compressor and indoor/outdoor fan is as same as DRY OPERATION.(11-2.3.)
4. Coil frost prevention
Coil frost prevention is as same as DRY OPERATION.(11-2.4.)
11-5-3. HEAT mode of "I FEEL CONTROL" <MUH-A07/A09/A12WV>
1. Thermostat control
Thermostat control is as same as HEAT OPERATION.(11-4.1.)
2. Indoor fan speed control
Indoor fan speed control is as same as HEAT OPERATION.(11-4.2.)
3. High pressure protection
High pressure protection is as same as HEAT OPERATION.(11-4.3.)
4. Defrosting
Defrosting is as same as HEAT OPERATION.(11-4.4.)
5. R.V. coil control
R.V. coil control is as same as HEAT OPERATION.(11-4.5.)
Initial room temperature
MU & MUX type
26: or more
26: or more
25: or more,
25: or more,
less than 26:
less than 26:
more than
13:,
23: or more,
less than25:
less than 25:
less than 23:
) mode, set temperature is decided by the microprocessor based on the room temperature.
MUH type
Initial room temperature
minus 2:
Initial room temperature
minus 2:
90
Initial set temperature
24:
26:
1