Leak Testing - Lynx L30PSR Care & Use Manual

Professional grill
Table of Contents

Advertisement

Leak Testing

To Perform Leak Test
1)
Create a soapy solution of
equal parts mild dish washing
detergent and water.
2)
Confirm that all control knobs
are in the off position.
3)
Turn on fuel supply. For natu-
ral gas, turn valve handle 1/4 turn
to align with gas flow. For L.P.,
turn cylinder valve knob counter
clockwise one full rotation.
4)
Apply soap solution gener-
ously by paint brush or squirt
bottle on all connections and
fittings, as indicated in figures 1
and 2.
5)
If "growing" bubbles appear
on any of the connection points,
then you have detected a gas
leak. IMMEDIATELY turn off the
gas supply by reversing step 3.
Fixing a Gas Leak
1)
After shutting off gas sup-
ply, push in and turn on control
knobs to release pressure, then
turn the knobs back to off.
2)
Wash off soapy solution with
cold water and towel dry.
3)
Stop a leak by tightening
the loose joint, or by replacing
the faulty part with a replace-
ment part recommended by the
manufacturer. DO NOT attempt
to repair the L.P. cylinder valve if
it should become damaged; the
cylinder MUST BE REPLACED.
4)
Perform a new leak test to en-
sure that no leaks are present.
C A U T I O N
To prevent fire or explosion hazard, DO NOT use or
permit sources of ignition in the area while perform-
ing a leak test. Perform leak test outdoors only. Never
perform a leak test with fire or flame. DO NOT SMOKE
WHILE PERFORMING THE LEAK TEST!
Figure 11-1 -
Leak testing points when using natural gas.
Figure 11- -
Leak testing points when using L.P. gas.
D A N G E R
11