REMOVING THE HOT SURFACE INDICATORS
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range.
Replace all panels before operating range.
Failure to do so can result in death or electri-
cal shock.
CAUTION: When you work on the electric
range, be careful when handling the sheet
metal parts. Sharp edges may be present, and
you can cut yourself if you are not careful.
1.
Turn off the electrical supply going to the
range.
2.
Pull the range away from the wall so that
you can access the rear panel.
3.
Remove the eight screws from the rear
panel and remove the panel (see step 4 on
page 3-2).
4.
Raise the cooktop (see page 3-8 for the
procedure).
(4) Hot Surface Indicator Assembly
5.
Hot Surface
(1) Hot Surface
Indicator
3-10
To remove the four hot surface indica-
tor assembly:
a) Remove the two screws from the hot
surface indicator assembly bracket and
remove the assembly from the frame.
Screw
(1 of 2)
Indicator
Bracket
b) Unsnap four tabs on the hot surface
indicator assembly from the bracket
and remove the assembly.
Tabs
c) Disconnect the yellow, orange, brown,
and blue wires from the element termi-
nals.
d) From the back of the unit, disconnect
the white wire connector.
Tabs