WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
NORMAL BURNER/ACCUSIMMER
SWITCH (LF)
1 WH
2 V
3 V
A - OR
B - BU
NORMAL BURNER
POSITION
1 WH 2 V
3
A - OR
B - BU
ACCUSIMMER POSITION
1 WH 2 V
3
A - OR
B - BU
Refer to page 3-3 for the procedure for servic-
ing the Normal Burner/AccuSimmer switch.
1.
Disconnect the electrical power to the
range.
2.
Set the ohmmeter to the R x 1 scale.
3.
Turn the Normal Burner/AccuSimmer
switch to the Normal Burner position.
4.
Touch the ohmmeter test leads to termi-
nals 2 and A. The meter should indicate
continuity (0 Ω).
5.
Touch the ohmmeter test leads to termi-
nals 3 and A. The meter should indicate
continuity (0 Ω).
6.
Touch the ohmmeter test leads to termi-
nals 1 and A. The meter should indicate an
open (infinite) circuit.
7.
Turn the Normal Burner/AccuSimmer
switch to the AccuSimmer position.
8.
Touch the ohmmeter test leads to termi-
nals 1 and A. The meter should indicate
continuity (0 Ω).
9.
Touch the ohmmeter test leads to termi-
nals 2 and B. The meter should indicate
continuity (0 Ω).
10. Touch the ohmmeter test leads to termi-
nals 3 and B. The meter should indicate
continuity (0 Ω).
4-7