Whirlpool RF196LXK Technical & Service Manual page 20

Consumer services technical education group presents 30″ freestanding self-cleaning electric range
Table of Contents

Advertisement

During the AccuSimmer cycle, 120 VAC is
activated across the element(s). This reduc-
tion of voltage is achieved by use of the
AccuSimmer switch. The switch has two posi-
tions: Normal and AccuSimmer. There are two
ACCUSIMMER
SWITCH
2
3
1
B
A
internal contacts inside the switch, as shown
below. The Normal position provides a circuit
from L1 to L2 to create 240 VAC for the normal
burner (both coils of the element). The
AccuSimmer position provides a circuit from
L1 to neutral for 120 VAC.
2
A
B
2
A
B
* As Shown On Wiring Diagram
2-4
1
ACCUSIMMER
"ON" POSITION
1
NORMAL*
POSITION