Enabled
The iRMC restarts the system on O/S Boot Timeout, because it
assumes an operating system start-up error.
I
– If Enabled is set, the server may not operate as intended. For
example, the server may automatically turn off or restart
without any commands.
– When starting up the system by using ServerView Suite
DVD 1, be sure to disable the O/S Boot Timeout, even when
ServerView Agent has been installed on the system. If the
system starts up with this item enabled, the server may not
operate as intended. For example, the server may
automatically turn off or restart without any commands.
– When setting this function, refer to ServerView Suite manuals.
Action
Determines the action taken after the boot watchdog expires.
Continue
The system continues to run.
Reset
The system is restarted by a system reset.
Power Cycle
The system is restarted by a power cycle.
Timeout Value
Specifies the time after which the system is rebooted if enabled via O/S
Boot Timeout.
Allowed values are 0...100
0
Time monitoring is disabled.
1...100
The system is rebooted after the selected time (in minutes) has
expired.
Pressing the [+] key or the [- ] key increases or decreases this value.
ASR&R Boot Delay
Specifies the system reboot delay after the system shuts down as a
result of an error (e.g. excessively high temperature). The system is
rebooted after the set wait time has expired.
BX960 S1
Operating Manual
Server menu
81