Table of Contents

Advertisement

3. Press Enter at the ªStatus º display.
4. Use the arrow buttons to scroll to the ª
already set to Full menu mode, scroll to Full and press
5. User accuracy:
Service accuracy:
6. User accuracy:
Service accuracy:
The ªCreate plot / Measure plot º message displays.
7. Press the Up Arrow button to select ª Create plot. º
A ªCreating calibration plotº message displays while plotting.
8. Wait until the ªRemove media / Continueº message displays.
9. Press the Down Arrow button to ªContinue.º
The ªCreate plot / Measure plotº message displays.
10. Press the Down Arrow button to select ªMeasure plot.º
11. Rotate the plot so that the edge with arrows points to the leading edge, then reload
the plot with the arrow edge print side down.
12. The plotter will load the plot and then measure the alignment marks using the edge
sensor on the pen carriage.
13. Press the Down Arrow button to continue when the ªCalibrate done / Continueº
message is displayed and the plot is fed out. Accuracy calibration is complete.
A Calibration Plot may be saved and reused for future calibrations by selecting ªMeasure
plotº when calibration is necessary.
Utilitiesº main menu. Press Enter. If not
Scroll to the ª
Accuracy º submenu. Press Enter.
Simultaneously press the
Scroll to the ª
Recalibrate º submenu. Press Enter.
Scroll to the ª
Accuracy Calib º submenu. Press Enter.
Adjustments/Calibrations
Enter.
Enter and Up Arrow buttons.
(C) C2847-15a(UM)
7-5