Crown DCi 8 Operation Manual page 25

Network display models dci series
Table of Contents

Advertisement

DriveCore Install Network Display Series Power Amplifiers
Software System Configuration
Bridge Mode Hi-Z (140V/200V)
Typical input and output wiring, along with software settings
are shown in Figures 26 and 27.
INPUTS: Connect the input to the odd-numbered channels
(1,3,5,7) only. Even-numbered inputs are disabled when the
Bridge Mono mode is active.
OUTPUTS: Connect the speaker across the positive terminals
of each channel pair. Do not use the negative terminals of the
channel pair when the pair is being operated in Bridge-Mono
mode.
Figure 26 System Wiring for 140V/200V Operation
Figure 27 Operation mode for 140Vrms or 200Vrms.
Always route the input and output wires in separate bundles.