Cable Diagnostics - Planet GSW-1602SF User Manual

10/100/1000mbps 16/24-port web smart gigabit ethernet switch
Hide thumbs Also See for GSW-1602SF:
Table of Contents

Advertisement

The Ping Parameters includes the following fields: Table 4-36 Description of the Ping Parameters.
Item
Description
Enter the IP address of the station you want the Web Smart Gigabit Switch to ping. The initial
Target IP Address
value is blank. The IP Address you enter is not retained across a power cycle.
Number of echo requests to send
Count
Timeout in milliseconds to wait for each reply.
Time Out (in secs)
Button
Press this button for save current configuration of Web Smart Gigabit Switch.
Apply
After field the parameter and press "Apply" to execute the Ping function. The Ping result shows at the next table. As the
screen in
Figure 4-84
appears.
Be sure the target IP Address is within the same network subnet of the Web Smart Gigabit Switch, or
you had setup the correct gateway IP address.

4.13.2 Cable Diagnostics

The Cable Diagnostics page contains fields for performing tests on copper cables. These functions have the ability to
identify the cable length and operating conditions, and to isolate a variety of common faults that can occur on the Cat5
twisted-pair cabling. There might be two statuses as follow:
If the link is established on the twisted-pair interface in 1000BASE-T mode, the Cable Diagnostics can run without
disruption of the link or of any data transfer.
If the link is established in 100BASE-TX or 10BASE-T, the Cable Diagnostics cause the link to drop while the
diagnostics are running.
After the diagnostics are finished, the link is reestablished. And the following functions are available.
• Coupling between cable pairs.
Table 4-36 Description of the Ping Parameters
Figure 4-84 Ping Result screen
-115-
User's Manual of GSW-1602SF / GSW-2404SF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsw-2404sf

Table of Contents