Omron GQ-CRM21 Operation Manual page 68

Componet gateway unit for cc-link

Advertisement

CC-Link Status
• Remote Inputs (RX)
Bit address*1
RXn0
RXn1
RXn2
RXn3
RXn4
4
RXn5
RXn6
RXn7
• Remote Outputs (RY)
Bit address*1
RYn0
RYn1
RYn2
RYn3
RYn4
RYn5
RYn6
RYn7
*1 "n" depends on the communications mode as shown below when the first refresh device address in the remote
input (RX) area or remote output (RY) area is 0 and the station number of the Gateway Unit is 1.
Communications mode 0 or 4: 10, Communications mode 1 or 5: C, Communications mode 2: 6, or Communi-
cations mode 3: 2.
*2 These flags are disabled because the Gateway Unit does not require initialization.
*3 The Error Status Flag will not automatically turn OFF even if the cause of the error is removed.
Remove the cause of the error, and then turn ON the Error Reset Request Flag.
*4 This flag turns ON when the power supply is turned ON or after resetting with the reset switch.
4 - 13
Initial Data Processing Request Flag*2
Initial Data Setting Completed Flag*2
Error Status Flag*3
Remote Station Ready Flag*4
Reserved.
Defined by OS.
Initial Data Processing Completed Flag*2
Initial Data Setting Request Flag*2
Error Reset Request Flag*3
Reserved.
Defined by OS.
Error occurred.
OFF
Error Status Flag
Error Reset
OFF
Request Flag
Remote Station
Ready Flag
Name
Name
ON
ON
OFF
CompoNet Gateway Unit for CC-Link Operation Manual