Download Print this page

Philips EM1A Servise Manual page 13

Colour television chassis

Advertisement

4.2.3
Accessing the Double Window (DW) panel
Multi Voltage
4
3
4
Figure 4-6
1. Remove the DW bracket from the bottom tray by pulling
it backward (after pressing the fixation clamp).
2. The board can easily be lifted out of the bracket [2] after
releasing the 2 fixation clamps [1].
4.2.4
Accessing the Multi Voltage panel (if present)
1. Remove the DW bracket from the bottom tray by pulling
it backward.
2. Press the 2 fixation clamps downward [3] (see figure 4-
7).
3. The board can easily be lifted out of the bracket after
releasing the 2 fixation clamps [4].
4.2.5
Accessing the Double Astigmatic Focus (DAF) panel
3
3
Figure 4-7
Mechanical instructions
PIP/Double Window
1
1
2
CL 06532130_015.eps
031000
3
2
1
CL 06532130_016.eps
031000
EM1A
1. The complete module can be removed from the LSP-
bracket by pressing its fixation clamp [1] (located behind
the PWB), while sliding the module in the direction of the
CRT [2].
2. The board can easily be lifted from its bracket after
releasing the 2 fixation clamps [3].
4.2.6
Accessing the Mains Harmonic panel
Figure 4-8
1. The complete module can be removed from the LSP-
bracket (after removal of the DAF-panel) by removing
screw [1] and then slide the module in the opposite
direction of the CRT [2].
2. The board can easily be lifted from its bracket after
releasing the 2 fixation clamps [3].
4.2.7
Accessing the Top Control panel
M
Figure 4-9
1. Remove the two fixation screws, which hold the panel.
2. Pull the board backward (w.o.w. release it from its front
hinge [M]).
3. The board can easily be lifted from its bracket after
releasing the 2 fixation clamps at the connector side.
4.
GB 13
1
3
2
3
3
CL 06532130_017.eps
131000
Top control board
CL 06532012_003.eps
030200

Advertisement

loading