TROUBLESHOOTING

Troubleshooting
These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
Case
Operation does not start soon.
• When ON/OFF button was pressed
soon after operation was stopped.
• When the mode was reselected.
A sound is heard.
Hot air does not flow out soon
after the start of HEAT
operation.
The HEAT operation stops
suddenly and a flowing sound
is heard.
The outdoor unit emits water or
steam.
Mist comes out of the indoor
unit.
The indoor unit gives out odour. ■ This happens when smells of the room, furniture, or cigarettes
The outdoor fan rotates while
the air conditioner is not in
operation.
30
• This is to protect the air conditioner.
You should wait for about 3 minutes.
■ A sound like a flow of water
• This sound is generated because the refrigerant in the air
conditioner is flowing.
• This is a pumping sound of the water in the air conditioner
it is heard when the water is pumped out from the air
conditioner in cooling or drying operation.
• The refrigerant flows in the air conditioner even if the air conditioner
is not working when the indoor units in other rooms are in operation.
■ Blowing sound
• This sound is generated when the flow of the refrigerant in
the air conditioner is switched over.
■ Pinging sound
• This sound is generated when the size of the air conditioner
slightly expands or shrinks as a result of temperature changes.
• The air conditioner is warming up. You should wait for 1 to 4 minutes.
(The system is designed to start discharging air only after it
has reached a certain temperature.)
• The outdoor unit is taking away the frost.
The HEAT operation starts after the frost on the outdoor unit is removed.
You should wait for about 4 to 12 minutes.
■ In HEAT mode
• The frost on the outdoor unit melts into water or steam
when the air conditioner is in defrost operation.
■ In COOL or DRY mode
• Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.
■ This happens when the air in the room is cooled into mist by
the cold airflow during cooling operation.
■ This is because the air in the room is cooled by the heat
exchanger and becomes mist during defrost operation.
are absorbed into the unit and discharged with the airflow.
(If this happens, we recommend you to have the indoor unit washed by a
technician. Consult the service shop where you bought the air conditioner.)
■ After operation is stopped:
• The outdoor fan continues rotating for another 60 seconds
for system protection.
■ While the air conditioner is not in operation:
• When the outdoor temperature is very high, the outdoor
fan starts rotating for system protection.
Explanation