DAIKIN AIR CONDITIONER
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION
Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
WARNING
• Installation should be left to the dealer or another professional.
• Install the air conditioner according to the instructions given in this manual.
• Be sure to use the supplied or specified installation parts.
• Install the air conditioner on a solid base that can support the weight of the unit.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection. Do not use an extension cord.
Do not put other loads on the power supply, use a dedicated power circuit.
The power supply wire class for the receptacle for the outdoor unit must be polychlorinated vinyl insulation or higher.
• Use the specified types of wires for electrical connections between the indoor and outdoor units. When installing
wiring for the outdoor unit, after cutting the wires for each connection point, a length of 3mm or longer is required.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire. When electrical appliances are connected in Y formation,
if the power supply is damaged in some way, to avoid danger the power supply must be replaced by the maker or by someone with an equivalent certification.
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the specified
refrigerant (R410A), such as air.
• The installation height from the floor must be over 1.8m.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• During pump-down, stop the compressor before removing the refrigerant piping.
pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
open during pump-down, air will be sucked in when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
• Note for installing the outdoor unit. (For heat pump model only.)
unit's drain may freeze. If so, it is recommended to install an electric heater in order to protect drain from freezing. It is recommended that you contact the after-sales service organization.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
Safety Precautions
Be sure to establish an earth connection.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
Failure to install an earth leakage breaker may result in electric shocks, or fire.
In cold area where the outside air temperature keep below or around freezing-point for a few days, the outdoor
3P182980-4D M06B012B
Improper installation may cause water leakage, electrical shock, or fire.
Incomplete installation may cause water leakage, electrical shock, or fire.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
If the compressor is still running and the stop valve is open during
Inadequate piping may cause flooding.
Never attempt.
(Failure to do so may cause abnormal heat, electric shock or fire.)
If the compressor is not attached and the stop valve is
Two-dimensional bar code
is a code for manufacturing.

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXS80FVMA

  • Page 1 3P182980-4D M06B012B DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety.
  • Page 2: Choosing An Installation Site

    Accessories Indoor unit fixing screws Mounting plate Wireless remote controller M4 × 12L Mounting plate fixing Remote controller holder Insulation tape screws M4 × 25L Fixing screws for remote Operation manual Titanium Apatite controller holder M3 × 20L Photocatalytic AAA dry-cell batteries Installation manual Air-Purifying Filter Choosing an Installation Site...
  • Page 3: Indoor Unit Installation Drawings

    Indoor Unit Installation Drawings How to attach the indoor unit. A Mounting Hook the claws of the bottom frame plate to the mounting plate. If the claws are difficult to hook, Clip remove the front grille. A Mounting plate How to remove the indoor unit. Bottom frame Push up the marked area (at the lower part of the front grille) to...
  • Page 4: Indoor Unit Installation

    Indoor Unit Installation (1) Installing the mounting plate. • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
  • Page 5: Installing Indoor Unit

    Indoor Unit Installation (2) Installing indoor unit. 3-1. Right-side, right-back, or right-bottom piping. 1) Attach the drain hose to the underside of the refrigerant pipes with an adhesive vinyl tape. 2) Wrap the refrigerant pipes and drain hose together with an Right-back piping Remove pipe port cover insulation tape.
  • Page 6: When Connecting To An Ha System

    Indoor Unit Installation (3) Wiring. , install as described in the installation With a Multi indoor unit Terminal block manual supplied with the Multi outdoor unit. Electrical component box 1) Strip wire ends (15mm). Shape wires so that the service 2) Match wire colours with terminal numbers on indoor and lid will fit securely.
  • Page 7: Refrigerant Piping Work

    Refrigerant Piping Work , install as described in the installation manual supplied with the Multi outdoor unit. With a Multi indoor unit Flaring the pipe end. (Cut exactly at 1) Cut the pipe end with a pipe cutter. right angles.) Remove burrs 2) Remove burrs with the cut surface facing Flaring...
  • Page 8: Trial Operation And Testing

    Trial Operation and Testing Trial operation and testing. 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. For Heat pump • In cooling mode, select the lowest programmable temperature;...