The blinking arrow under IRON/FOIL disappears and IR
appears in the TARGET readout (indicating that the detector is
set to accept all metals, including all levels of iron) as shown
in the following diagram.

To select PRESET targets

The Land Ranger' has three PRESET modes:
PRESET 1
PRESET 2
PRESET 3
1. Perform the steps described in Turning the Detector ON section of
this manual.
2. Press the DISC TARGET touch pad.
A blinking arrow appears under IRON/FOIL in the Probable
Target ID fields, meaning the detector is ready for programming.
3. Press the PRESET touch pad once to select PRESET 1.
The blinking arrow under IRON/FOIL is replaced by an R.
4. Press the PRESET touch pad twice to select PRESET 2.
An R appears under PULL TAB in the Probable Target ID fields.
5. Press the PRESET touch pad three times to select PRESET 3.
An R appears under Z-1¢/S-CAP in the Probable Target ID fields.
Rejects all levels of iron and aluminum foil.
Rejects pull-tabs, iron and all objects rejected in PRESET 1 mode.
Rejects zinc pennies, screw-caps, pull-tabs, aluminum, other similar
objects, and all objects rejected in PRESET 1 and PRESET 2
modes.