Security Codes & Authority Levels (cont'd)
RF BUTTON ?
0 = NO , 1 = YES
ENTER BUTTON ZN #
(001-128)
MULTI-ACCESS ?
0 = NO , 1 = YES
GLOBAL ARM ?
0 = NO , 1 = YES
PART.2 - SHOP?
0 = NO , 1 = YES
This prompt will appear if a 5800 series
button transmitter has been supplied and has
not yet been assigned to a user. Press 1 if a
button transmitter will be assigned to this
user. Otherwise press 0.
If assigning a button transmitter, this prompt
will appear. Enter the button's zone number
(see your installer for zone number).
If you as a user have access to other
partitions, the keypad will prompt for ability
of this new user to access (GOTO) those
partitions. Press 0 (NO) or 1 (YES). If no, the
system activates this user code and exits "Add
a User" mode. If yes, the keypad prompts for
the Global Arm option for this user.
Press 1 (YES) if this user will be allowed to
try to arm more than one partition at the
same time. Press 0 if this user will arm only
his assigned partition.
The keypad now prompts for the user's access
to the next partition (see GOTO command).
Again press 0 or 1. If yes, the system will
automatically assign a user number for use in
that partition and will prompt for the
authority level and global arm option for this
user within the partition (see previous steps).